Dynamic contrast-enhanced MRI and Apparent diffusion coefficient mapping in the characterization of Palpable breast lesions: A prospective observational study

Author:

Boruah Deb K.ORCID,Konwar Nitashree,Gogoi Bidyut B.,Hazarika Karuna,Ahmed Halimuddin

Abstract

Abstract Background Breast MRI is the imaging modality of choice in patients with palpable breast lesions unequivocal on mammography and ultrasonography. This study aims to evaluate the role of dynamic contrast-enhanced MRI (DCE-MRI) and apparent diffusion coefficient mapping in the characterization and differentiation of various palpable breast lesions. This prospective observational study was conducted in a tertiary care hospital between July 2019 and June 2021. Sixty-six patients with palpable breast lesions were undergone MRI scans of the breasts. The various palpable breast lesions were categorized according to the 5th edition BI-RADS lexicon. The sensitivity of ADC mapping and DCE-MRI was determined for differentiation of various palpable breast lesions according to the BI-RADS category and gold standard histopathological findings. Results Of 66 patients with palpable breast lesions, 36 patients (54.5%) were benign and 30 patients (45.5%) were malignant lesions. Malignant palpable breast lesions had a mean ADC value of 0.939 ± 0.166[SD] × 10−3 mm2/s, and benign lesions had 1.891 ± 0.524[SD] × 10−3 mm2/s where unpaired Student t-test showed statistically significant difference of P value 0.0005. BI-RADS 2 lesions had a mean ADC value of 2.056 ± 0.471[SD] × 10−3 mm2/s, BI-RADS 3 had 1.314 ± 0.151[SD] × 10−3 mm2/s, BI-RADS 4 had 0.935 ± 0.119[SD] × 10−3 mm2/s, and BI-RADS 5 had 0.930 ± 0.943[SD] × 10−3 mm2/s. BI-RADS 2 category showed optimal cutoff mean ADC of 1.508 × 10−3 mm2/s with a sensitivity of 85.7% and specificity of 94.7%, BI-RADS 3 lesions had 1.208 × 10−3 mm2/s with a sensitivity of 75% and specificity of 55.2%, BI-RADS 4 lesions had 1.064 × 10−3 mm2/s with a sensitivity 80% and specificity of 67.9%, and BI-RADS 5 lesions had 1.013 × 10−3 mm2/s with a sensitivity of 80% and specificity of 82.6%. Conclusions Breast MRI is superior to the other imaging modalities for the characterization and differentiation of various palpable breast lesions. The combined use of ADC mapping and DCE-MRI had more sensitivity than conventional MRI, ADC mapping or DCE-MRI alone.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3