Abstract
Abstract
Background
Traditionally, the placental functional integrity is suggested by indirect ultrasound measurements like fetal growth, amniotic fluid index, and uterine and umbilical artery Doppler indices. Only recently the elasticity of the placenta is studied as a measure of placental consistency and biomechanical prosperities and may reflect the placental function. Shear wave velocity is the quantitative parameter of the shear wave elastography. A high-risk pregnancy is a situation which puts the mother, the fetus, or both at greater risk than a normal pregnancy.
Results
The shear wave velocity (SWV) showed no significant difference between the placenta of normal pregnancies in the second and third trimesters (0.85 ± 0.43 m/s and 0.89 ± 0.57 m/s, respectively). The placenta of patients with preeclampsia/eclampsia had high SWV in the second and third trimesters (2.13 ± 1.48 m/s and 2.23 ± 1.48 m/s) with a highly significant difference from the normal placenta (P < 0.001). The placentas with abnormal location (placenta previa) and penetration (placenta accreta) had higher SWV than the placenta of normal pregnancies. The mean SWV for placenta previa was 1.1 ± 0.74 m/s and 1.3 ± 0.81 m/s in the second and third trimesters, respectively, with a mildly significant difference with the normal placenta. The placenta accreta shows high mean SWV in the second and third trimesters (1.6 ± 0.65 m/s and 1.961.6 ± 0.65, respectively) which differed significantly (P < 0.001) from SWV in the normal placenta in the second and third trimesters.
Conclusion
Shear wave velocity measurement as the quantitative parameter of acoustic radiation force impulse (ARFI) elastography reflects the placental elasticity in normal and high-risk pregnancies. The SWV increases in conditions like hypertension, preeclampsia, maternal renal disease, and diabetes and reflects the structural and biomechanical abnormalities in such diseases. High shear wave velocity correlates with the incidence of growth restriction and abnormal Doppler parameters especially in the hypertensive disease. The virtual touch quantification (VTQ) can be used as a complementary diagnostic and prognostic tool in high-risk pregnancy.
Publisher
Springer Science and Business Media LLC
Subject
Radiology Nuclear Medicine and imaging
Reference47 articles.
1. Kuhlmann RS, Warsof S (1996) Ultrasound of the placenta. Clin Obstet Gynecol 39:519–534
2. Smith GC, Smith MF, McNay MB, Fleming JE (1997) The relation between fetal abdominal circumference and birth weight: findings in 3512 pregnancies. Br. J. Obstet. Gynaecol. 104(2):186–190
3. Bricker L , Medley N, Pratt JJ. Routine ultrasound in late pregnancy (after 24 weeks’ gestation). Cochrane Database Syst 2015 . Rev. 6, CD001451
4. Chauhan SP, Rouse DJ, Ananth CV, Magann EF, Chang E, Dahlke JD et al (2013) Screening for intrauterine growth restriction in uncomplicated pregnancies: time for action. Am. J. Perinatol. 30(1):33–39
5. Habibi A, Davutoglu A, Kandemirli SG, Alan M, KalyoncuUcar A, Zeytun P et al (2017) In vivo assessment of placental elasticity in intra uterine growth restriction by shear wave elastography. Eur J Radiol. 97:16–20
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献