Diagnostic value of three-dimensional cube fluid attenuated inversion recovery imaging and its axial MIP reconstruction in multiple sclerosis

Author:

Zamzam Alaa Elsayed Abdelkader,Aboukhadrah Rania SobhyORCID,Khali Mohammed Mohammed,Khodair Sameh Ahmed Zaki

Abstract

Abstract Background Magnetic resonance imaging is regarded as one of the most important markers for multiple sclerosis. It can detect lesions in order to establish dissemination in time and space, which would aid in the diagnosis. Two-dimensional FLAIR is a standard sequence in MS routine imaging because it suppresses cerebrospinal fluid signal, increasing contrast between lesions and CSF and improving white matter lesion detection. Newer 3D FLAIR sequences are expected to offer even more benefits, such as improved MS lesions detection and higher resolution due to thinner slice thickness. We aimed to compare the role of 3D Cube FLAIR imaging (versus standard 2D FLAIR) in the assessment of white matter lesions in MS patients, as well as to test the convenience of using maximum intensity projection (MIP) on 3D FLAIR images for faster and easier evaluation. Results This study included 160 MS patients. A 1.5 T routine brain MRI scan was performed, which included a 2D FLAIR sequence, followed by a 3D-FLAIR sequence. All images were analyzed after 3D-FLAIR images were reformatted into axial MIP images. Lesions were counted in each sequence and classified into supra-tentorial (periventricular, deep white matter, and juxta-cortical), and infra-tentorial lesions, with the relative comparison of lesions numbers on 3D-FLAIR and MIP versus 2D-FLAIR expressed as a percentage increase or decrease. 3D FLAIR can significantly improve MS lesion detection in all areas of the brain when compared with 2D FLAIR results. At 2 mm reformatting, there is no difference in MS lesion detection between sagittal 3D FLAIR and axial MIP reconstruction, implying that the MIP algorithm can be used to simplify lesion detection by reducing the number of images while maintaining the same level of reliability. Conclusion 3D FLAIR sequences should be added to conventional 2D FLAIR sequences in the MRI protocol when MS is suspected.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3