Values and validity of fetal parameters by ultrasound and Doppler as markers of fetal lung maturity

Author:

Kandil Radwa A.,El shahawy Al shymaa Z.,El Shafiey Mohamed H.,Alarabawy Reda A.

Abstract

Abstract Background In this study, we combined ultrasound and Doppler parameters to conclude the most accurate and applicable method for fetal lung maturity assessment. Thepurpose is to reduce risk of neonatal respiratory distress by assessment of fetal lung maturity through ultrasound and Doppler instead of amniocentesis. Results A total of 120 women were included. The ultrasound examination was performed at a gestational age ranging between 30 and 37 weeks and delivery occurred within 72 h from ultrasound. After birth, 19 fetuses were diagnosed with RDS. The ultrasound parameters assessed for fetal lung maturity showed varying sensitivity and specificity but presence of proximal tibial epiphyses showed the highest sensitivity (91%) and specificity (95%) followed by the presence of distal femoral epiphyses with 90% sensitivity and 84% specificity. The placental grade III maturity showed a sensitivity of 81% and 74% specificity followed by the presence of the amniotic fluid free-floating particles with an 83% sensitivity and 63% specificity, while echogenic fetal thalamus showed 77% and 79% for sensitivity and specificity, respectively, for prediction of fetal lung maturity. By using the fetal biometry, we could report that a BPD between 82.8 and 93.5 mm, AC between 295 and 322 mm, and FL (62.7-72.1 mm) correlated with mature fetal lungs. Regarding Doppler indices, increased resistive index of umbilical artery > 0.69 and of pulmonary artery > 0.78 correlated with neonatal RDS while fetuses with UtA RI values between 0.43 and 0.66 noticed in RDS vs (0.42-0.57) in the non-RDS. MCA RI values are also higher in RDS 0.77–0.88 vs 0.74–0.79 in non-RDS. On the other hand, analysis of colon grading and fetal lung echogenicity in relation to liver showed no significant value in the assessment of fetal lung maturity. Conclusion Ultrasound and Doppler showed good predictive value and accuracy and is considered a valuable non-invasive procedure in assessment of fetal lung maturity. However, no single parameter alone could show a definitive sign

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Reference24 articles.

1. Khanipouyani F, Abbasalizade F, Abbasalizade S, Fardiazar Z, Ghaffari S, Sarbakhshi P, editors. Predicting fetal lung maturity using the fetal main pulmonary artery doppler indices. 2016.

2. Ghorayeb SR, Bracero LA, Blitz MJ, Rahman Z, Lesser ML (2017) Quantitative ultrasound texture analysis for differentiating preterm from term fetal lungs. J Ultrasound Med 36(7):1437–1443

3. Pallavi L, Sushil K, Lakhkar DL, Soniya D, Abhijeet I, Pooja S (2017) Assessment of fetal lung maturity by ultrasonography. Ann Int Med Den Res 3(4):RD01–RD04

4. Loret de Mola JR, Judge N, Entsminger C, DeViney M, Muise KL, Duchon MA (1998) Indirect prediction of fetal lung maturity. Value of ultrasonographic colonic and placental grading. J Reprod Med 43(10):898–902

5. Tahilramaney MP, Platt LD, Golde SH (1991) Use of femur length measured by ultrasonography to predict fetal maturity. J Perinatol 11(2):157–160

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3