99mTc-DMSA renal cortical scanning: a comparison of planar, SPECT, and SPECT/CT imaging for the detection of renal cortical scarring

Author:

Mohamadien Nsreen R. A.,Mohamed Marwa S.,Mekkaway Mohamed A.,Ali Wageeh A.ORCID,Diab Waleed A.

Abstract

Abstract Background The best way to assess renal cortical scarring is planar scintigraphy with 99mTc-dimercaptosuccinic acid (DMSA), while the value of single-photon emission computed tomography/computed tomography (SPECT/CT) is not well validated. The aim of the present study was to assess the value of planar, SPECT, and SPECT/CT scanning using 99mTc-DMSA in detecting renal cortical scarring. Methods Patients with clinically suspected renal cortical scar were included in this prospective cohort. 99mTc-DMSA Planar images were obtained approximately 3–4 h after intravenous injection (IV) of 185 MBq of the tracer. SPECT/CT scans were obtained immediately after the planar ones. An expert nuclear medicine doctor who was unaware of the patient's clinical history or any previous imaging results analyzed the images. Each kidney was given a score of 0 for no obvious defects, 1 for equivocal lesions, 2 for a single defect, 3 for several defects, and 4 for non-visualized/non-functioning kidney (in CT images). The results of each method were then compared to each other. Results One hundred eighty-six kidneys from ninety-three individuals were eligible for assessment. Planar scans detected 21 kidneys with equivocal lesions, 5 with single and 7 with multiple defects. SPECT scans detected 17 kidneys with single and 40 with multiple defects, while SPECT/CT scans revealed 5 with single and 11 with multiple defects. Only 5 of the 17 kidneys with single defects diagnosed by SPECT imaging had a scar in the SPECT/CT scans, whereas the remaining 12 had a solitary cortical cyst in the CT images. Only 11 of 40 kidneys with multiple defects on SPECT were shown to have a scar in the corresponding SPECT/CT images, whereas the rest matched to either hydro-nephrotic changes or multiple cortical cysts. Four kidneys with multiple defects on the SPECT/CT images were normal in the planar readings, were ascribed to an increase in renal background activity and a reduction in renal function. Conclusions In cases with suspected renal cortical scar, 99mTc-DMSA SPECT/CT scanning outperformed both planar and SPECT imaging by reducing the number of false-positive SPECT readings and false-negative planar readings.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3