What’s beyond breast asymmetry? Comparative study between artificial intelligence and contrast-enhanced spectral mammography in the assessment of various types of breast asymmetries

Author:

Sobhi AalaaORCID,Mohammed Nada A.,Ali Engy A.

Abstract

Abstract Background Breast asymmetries are prevalent findings in mammograms and are commonly caused by variations in normal breast tissue. However, they may imply significant underlying causes in some cases. Such cases necessitate further assessment by adding further mammography views, targeted ultrasound, and investigations to exclude underlying pathology. Objectives To investigate the role of artificial intelligence (AI) compared to contrast-enhanced spectral mammography (CESM) in the assessment of breast asymmetries and their performance as diagnostic modality among different types of breast asymmetries as well as the additive value of AI software to mammography in these cases. Methods Sixty-four female patients were diagnosed with breast asymmetries by standard mammography (MMG) on both craniocaudal (CC) and mediolateral oblique (MLO). Digital breast tomosynthesis (DBT) may have been added. After evaluating the breast asymmetry by MMG and complementary breast ultrasound (US), both CESM and AI were performed for all cases and analyzed, then the interpreted results were compared accordingly either by histopathology from suspected lesions scored as BI-RADS 4 or 5 or through further close follow-up by single-view mammography in benign cases scored as BI-RADS 2 or 3. Results The sensitivity and specificity of CESM in the assessment of breast asymmetry in correlation with pathological data/follow-up results were 100% and 60% (p < 0.001). The corresponding values for AI were 70.83% and 75%; however, the estimated overall accuracy for both CESM and AI was close to each other measuring 75% and 73.44%, respectively (p < 0.001). The diagnostic accuracy of CESM to detect malignant causes of breast asymmetry was 100%; however, the detection of benign causes of breast asymmetry was 40%. The corresponding values for AI were 70.83% and 25%, respectively, with significant p-value (p < 0.001). Conclusions The CESM was more sensitive; however, the AI was more specific in the assessment of different breast asymmetries. Although the diagnostic accuracy of both is close to each other. Therefore, AI-aided reading can replace CESM in most cases, especially for those contraindicated to do CESM. AI also can reduce the radiation exposure hazards of a second dose of radiation for CESM and its financial cost as well. AI-aided reading in breast screening programs can reduce the recall of patients, unnecessary biopsies, and short-interval follow-up exams.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3