Implementation of a sagittal T2-weighted DIXON turbo spin-echo sequence may shorten MRI acquisitions in the emergency setting of suspected spinal bleeding

Author:

Sollmann NicoORCID,Rüther Charlotte,Schön Simon,Zimmer Claus,Baum Thomas,Kirschke Jan S.

Abstract

Abstract Background Magnetic resonance imaging (MRI) is the modality of choice for evaluating soft tissue damage along the spine in the emergency setting, yet access and fast protocol availability are limited. We assessed the performance of a sagittal T2-weighted DIXON turbo spin-echo sequence and investigated whether additional standard sagittal T1-weighted sequences are necessary in suspected spinal fluid collections/bleedings. Methods Seventy-four patients aged 62.9 ± 19.3 years (mean ± standard deviation) with MRI including a sagittal T2-weighted DIXON sequence and a T1-weighted sequence were retrospectively included. Thirty-four patients (45.9%) showed a spinal fluid collection/bleeding. Two layouts (layout 1: fat-only and water-only and in-phase images of the DIXON sequence and T1-weighted images; layout 2: fat-only and water-only and in-phase images of the DIXON sequence) were evaluated by three readers (R1, R2, and R3) concerning presence of spinal fluid collections/bleedings and diagnostic confidence from 1 (very low confidence) to 5 (very high confidence). χ2 and κ statistics were used. Results There was no difference in detecting spinal fluid collections/bleedings between the layouts (R1 and R2 detected all, R3 missed one spinal fluid collection/bleeding in the same patient in both layouts). Confidence was high (layout 1, R1 4.26 ± 0.81, R2 4.28 ± 0.81, R3 4.32 ± 0.79; layout 2, R1 3.93 ± 0.70, R2 4.09 ± 0.86, R3 3.97 ± 0.73), with higher inter-reader agreement for layout 1 (κ 0.691–0.780) than for layout 2 (κ 0.441–0.674). Conclusions A sagittal T2-weighted DIXON sequence provides diagnostic performance similar to a protocol including standard T1-weighted sequences.

Funder

Deutsche Gesellschaft für muskuloskelettale Radiologie, DGMSR

Technische Universität München

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3