Strategies for calculating contrast media dose for chest CT

Author:

Henning Mette Karen,Gunn Catherine,Arenas-Jiménez Juan,Johansen SaforaORCID

Abstract

Abstract Background Total body weight (TBW) is a frequently used contrast media (CM) strategy for dose calculation in enhanced CT, yet it is suboptimal as it lacks consideration of patient characteristics, such as body fat percentage (BFP) and muscle mass. Alternative CM dosage strategies are suggested by the literature. Our objectives were to analyze the CM dose impact when adjusting to body composition using methods of obtaining lean body mass (LBM) and body surface area (BSA) along with its correlation with demographic factors in contrast enhanced chest CT examinations. Methods Eighty-nine adult patients referred for CM thoracic CT were retrospectively included, categorized as either normal, muscular, or overweight. Patient body composition data was used to calculate the CM dose according to LBM or BSA. LBM was calculated with the James method, Boer method, and bioelectric impedance (BIA). BSA was calculated using the Mostellar formula. We then correlated the corresponding CM doses with demographic factors. Results BIA demonstrated the highest and lowest calculated CM dose in muscular and overweight groups respectively, compared to other strategies. For the normal group, the lowest calculated CM dose was achieved using TBW. The calculated CM dose was more closely correlated with BFP using the BIA method. Conclusions The BIA method is more adaptive to variations in patient body habitus especially in muscular and overweight patients and is most closely correlated to patient demographics. This study could support utilizing the BIA method for calculating LBM for a body-tailored CM dose protocol for enhanced chest CT examinations. Relevance statement The BIA-based method is adaptive to variations in body habitus especially in muscular and overweight patients and is closely correlated to patient demographics for contrast-enhanced chest CT. Key points • Calculations based on BIA showed the largest variation in CM dose. • Lean body weight using BIA demonstrated the strongest correlation to patient demographics. • Lean body weight BIA protocol may be considered for CM dosing in chest CT. Graphical Abstract

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3