Abstract
Abstract
Background
Real-time dosimeters may create a relatively safer environment not only for the patient but also for the physician and the assistant as well. We propose the use of a real-time radiation measurement dosimeter having auditory feedback to reduce radiation exposure.
Methods
Radiation dose rates were measured for 30 fluoroscopy-guided puncturing procedures of femoral arteries in swine. Fifteen puncturing procedures were performed with real-time radiation measurement dosimeter having auditory feedback and other 15 were performed without auditory feedback dosimeter by an interventional cardiologist with 10 years of experience.
Results
The left body side of the operating physician (38%, p < 0.001) and assistant (25%, p < 0.001) was more exposed as compared to the right body side. Radiation dose rate to the left hand, left arm and left leg were reduced from 0.96 ± 0.10 to 0.79 ± 0.12 mSv/h (17% reduction, p < 0.001), from 0.11 ± 0.02 to 0.07 ± 0.01 mSv/h (36% reduction, p < 0.001) and from 0.22 ± 0.06 to 0.15 ± 0.02 mSv/h (31% reduction, p < 0.001) with the use of auditory feedback dosimeter, respectively. The mean fluoroscopic time was reduced from 4.8 ± 0.43 min to 4.2 ± 0.53 min (p < 0.001). The success rate of performing arterial puncturing was 100%.
Conclusions
The use of auditory feedback dosimeter resulted in reduction in effective dose. The sound beep alerted the physician from the danger of exposure, and this approach induced awareness and protective mindset to the operating physician and assistant.
Publisher
Springer Science and Business Media LLC
Subject
Radiology, Nuclear Medicine and imaging
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献