Author:
Feng Houmei,Song Danyu,Xu Qiang,Cai Xiaohui,Liu Jianru,Zhang Yang,Zhou Zhou
Abstract
Abstract
Background
Inherited antithrombin, protein C, and protein S deficiency increase the risk of venous thromboembolism. The presence of defects can be identified by clinical laboratory assays. In most Chinese clinical laboratories, the screening tests for antithrombin, protein C, and protein S deficiency are their activity assays. Ensuring appropriate pre-analytical storage conditions for activity tests is essential. This study aimed to assess the effects of storage conditions on antithrombin, protein C, and protein S activity in frozen plasma.
Methods
We collected the remaining plasma of 29 patients. The baseline of antithrombin, protein C, and protein S activity values were tested within 4 h. Then, each sample was sub-packaged into 4 EP tubes, and was stored at -20 °C for 3 days, -20 °C for 7 days, -80 °C for 3 days, and − 80 °C for 7 days, respectively. After thawing, samples were tested by two systems.
Results
The percentage deviation of antithrombin and protein C activity assay was<10% compared with the initial values. Protein S activity showed a significant reduction in frozen plasma, with a deviation > 10%. Some samples, initially within the normal range, were classified as abnormal after freezing storage.
Conclusions
Our study indicated that antithrombin and protein C remain stable when stored at -20 °C or -80 °C in a week. We argued that Protein S activity is not stable in frozen plasma. The use of frozen-thawed plasma for PS activity assay may result in overdiagnosis of protein S deficiency.
Funder
CAMS Innovation Fund for Medical Sciences
Beijing Natural Science Foundation
Publisher
Springer Science and Business Media LLC
Reference20 articles.
1. De Stefano V, Simioni P, Rossi E, Tormene D, Za T, Pagnan A, et al. The risk of recurrent venous thromboembolism in patients with inherited deficiency of natural anticoagulants antithrombin, protein C and protein S. Haematologica. 2006;91(5):695–8.
2. Linnemann B, Hart C. Laboratory Diagnostics in Thrombophilia. Hamostaseologie. 2019;39(1):49–61.
3. Marlar RA, Gausman JN. Laboratory testing issues for protein C, protein S, and antithrombin. Int J Lab Hematol. 2014;36(3):289–95.
4. Van Cott EM, Orlando C, Moore GW, Cooper PC, Meijer P, Marlar R. Recommendations for clinical laboratory testing for antithrombin deficiency; communication from the SSC of the ISTH. J Thromb Haemost. 2020;18(1):17–22.
5. Cooper PC, Pavlova A, Moore GW, Hickey KP, Marlar RA. Recommendations for clinical laboratory testing for protein C deficiency, for the subcommittee on plasma coagulation inhibitors of the ISTH. J Thromb Haemost. 2020;18(2):271–7.