An objective measure for the assessment and management of fluid shifts in acute major burns

Author:

Kenworthy Pippa1234ORCID,Phillips Michael5,Grisbrook Tiffany L.16,Gibson William3,Wood Fiona M.12,Edgar Dale W.127

Affiliation:

1. Fiona Wood Foundation, Fiona Stanley Hospital Perth Western Australia, Australia

2. Burns Service of Western Australia Fiona Stanley Hospital Perth Western Australia, Australia

3. School of Physiotherapy Notre Dame University Fremantle Western Australia, Australia

4. Adult State Burns Service Fiona Stanley Hospital Murdoch Drive 6150 Murdoch Western Australia, Australia

5. Harry Perkins Institute of Medical Research The University of Western Australia Perth Western Australia, Australia

6. School of Physiotherapy and Exercise Science Curtin University Perth Western Australia, Australia

7. Burn Injury Research Node Notre Dame University Fremantle Western Australia, Australia

Abstract

Abstract Background Major burns are life threatening. Fluid resuscitation is required for survival to maintain intravascular volumes and prevent hypovolemic shock. Bioimpedance spectroscopy (BIS) has been recognised as a potential method of monitoring fluid shifts after burn and in other disease states. The aims of this study were to examine the reliability of BIS across different dressing conditions and electrode positions, establish the influence of Acticoat™ on BIS variable measures and determine the validity of whole-body BIS to assess net fluid shift in the presence of moderate to major burns. Methods An observational longitudinal cohort study was conducted from December 2014 to February 2016. Patients with over 15% total body surface area (TBSA) burns and injury less than 48 h were enrolled in the study. BIS triplicate measures were collected in an open wound and with an ActicoatTM dressing (at 5 half hour intervals). Standard and alternate electrode placements were utilised for the reliability analysis and standard placement only for determining the validity of BIS in moderate to major burns. The ImpediMde SFB7 was used to collect whole-body and segmental BIS measures. Stata statistical software, release 14 was utilised to analyse all results. Descriptive analyses were performed and were reported using the means and standard deviations (SD). Results BIS-repeated measures established BIS raw resistance (R), and predicted volume variables were reliable in any condition (intra-class correlation coefficient (ICC) 0.996–0.999, 95% confidence intervals (CI) 0.996–0.999) without a systematic difference. Acticoat™ dressings significantly influenced all BIS-predicted volumes (p ≤ 0.01) as determined by multilevel mixed effects (MLME) linear regression analysis. Validity of BIS was demonstrated by resistance variables significantly decreasing with increasing net ionic fluid shift and increased TBSA (severity of injury) and calculated fluid volumes increasing with increasing net fluid shift and TBSA. BIS resistance also decreased with time as oedema reduced. For clinical use, a calculator was developed to adjust BIS variables when an Acticoat™ dressing is in situ, thus facilitating BIS variable change estimates in real time, with dressings intact. Conclusion BIS may be used clinically to monitor fluid volume change in major acute burns.

Publisher

Oxford University Press (OUP)

Subject

Critical Care and Intensive Care Medicine,Dermatology,Biomedical Engineering,Emergency Medicine,Immunology and Allergy,Surgery

Reference54 articles.

1. Burn wound: how it differs from other wounds?;Tiwari;Indian J Plast Surg,2012

2. Burn resuscitation;Greenhalgh;J Burn Care Res,2007

3. The phenomenon of “fluid creep” in acute burn resuscitation;Saffle;J Burn Care Res,2007

4. Burn resuscitation;Alvarado;Burns,2009

5. Protection from excessive resuscitation: “pushing the pendulum back”;Pruitt;The J Trauma,2000

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3