Inferior vena cava collapsibility index as a predictor of fluid responsiveness in sepsis-related acute circulatory failure

Author:

Nagi Ahmed Ibrahim,Shafik Azza Mohamed,Fatah Amr Mohamed Abdel,Selima Wessam Zaher,Hefny Amira Fathy

Abstract

Abstract Background Assessing fluid responsiveness is the key to successful resuscitation of critically-ill sepsis patients. The use of IVC variation is favored among the dynamic methods of fluid responsiveness assessment in the ICU because it is non-invasive and inexpensive; moreover, it does not demand a high level of training. The aim of this study is to determine the value of the IVC respiratory variability for predicting fluid responsiveness in spontaneously breathing sepsis patients with acute circulatory failure. Results In this prospective observational study, fifty-eight spontaneously breathing sepsis patients admitted in the ICU were enrolled after the approval of the departmental Research Ethical Committee, and the informed written consent had been taken from the patients. Ultrasonographic and echocardiographic parameters were measured “IVC parameters and stroke volume (SV)” with calculation of the inferior vena cava collapsibility index (IVCCI) and cardiac output. These values were obtained before (baseline) and after volume expansion with a fluid bolus. The study showed that twenty-nine patients (50%) were considered to be responders, with an increase in CO by 10% or more after fluid challenge. There was a significant difference between responders and non-responders in baseline IVCCI (p value < 0.001). There were no significant differences between responders and non-responders in terms of demographic and baseline clinical characteristics. Also, there was statistically significantly larger maximum (IVC max) and minimum (IVC min) inferior vena cava diameters before volume expansion in non-responders than in responders with p value 0.037 and 0.001 respectively. The suggested cut off value regarding baseline IVCCI to predict response to fluid infusion is 0.32 with a high chance of response above this figure (a sensitivity of 72.41% and a specificity of 82.76%). Conclusions Inferior vena cava collapsibility index assessment can be a sensitive and a good predictor of fluid responsiveness, being based on a safe and a non-invasive technique compared to other methods such as central venous pressure (CVP) measurement and pulmonary artery catheter insertion.

Publisher

Springer Science and Business Media LLC

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3