Ultrasound-assessed diaphragmatic dysfunction as a predictor of weaning outcome in mechanically ventilated patients with sepsis in intensive care unit

Author:

Saad Mohamed AhmedORCID,Nashed Sherif Wadie,El-Shaer Ahmed Nagah,Elagamy Ashraf Elsayed,El derh Maha Sadek

Abstract

Abstract Background Weaning from mechanical ventilation is one of the most common challenges in the intensive care unit (ICU). Most of predictive indices of weaning from mechanical ventilation are often inaccurate. This study was performed to assess the accuracy of diaphragmatic ultrasonography for predicting weaning outcome in mechanically ventilated patients with sepsis in ICU. Results Sixty patients with sepsis in medical ICU were prospectively enrolled. All patients were ventilated in pressure support. Patients underwent a spontaneous breathing trial (SBT) on T-piece when they met all the following criteria: FiO2 < 0.6, PEEP ≤5 cmH2O, PaO2/FiO2 > 200, respiratory rate <30 breaths per minute, absence of fever, alert and cooperative, hemodynamic stability without or with low-dose vasoactive therapy support, and rapid shallow breathing index (RSBI)<105. During the trial, the patient was instructed to perform deep breathing to total lung capacity (TLC) and then exhaling to residual volume (RV) and the diaphragm was visualized in the 8th or 9th intercostal space between anterior and mid-axillary lines using a 3–5-MHz curved ultrasound probe to measure diaphragmatic excursion (DE) and a 7–11-MHz linear ultrasound probe to measure diaphragmatic thickness (DT) at TLC and RV, and the diaphragmatic thickness fraction (DTF) was calculated as percentage from the following formula (thickness at end inspiration—thickness at end expiration)/thickness at end expiration. According to weaning outcome, patients were divided into 2 groups: successful weaning group and weaning failure group. Weaning failure was defined as the inability to maintain spontaneous breathing for at least 48 h, without any form of ventilatory support. In the present study, right DTF of more than 37% and DE during deep breathing of more than 6.1 and 5.4 cm on the Rt and Lt side, respectively, were associated with successful weaning from MV. In the study, the sensitivities for right and left DE and DTF were 58.33, 62.5, and 58.33%, respectively, and the pooled specificities were 83.33, 83.33, and 100%, respectively, with p value = 0.032, 0.028, and 0.001, respectively. The area under curve (AUC) for Rt, Lt DE, and DTF were 0.701, 0.712, and 0.840, respectively. The present data indicate a satisfactory diagnostic accuracy in predicting extubation outcome. Conclusions Ultrasonography-based determination of diaphragm function by assessing DTF and DE can be used as predictor of weaning outcome in mechanically ventilated patients with sepsis.

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3