A novel method of calculating stroke volume using point-of-care echocardiography

Author:

Aligholizadeh EhsonORCID,Teeter William,Patel Rajan,Hu Peter,Fatima Syeda,Yang Shiming,Ramani Gautam,Safadi Sami,Olivieri Peter,Scalea Thomas,Murthi Sarah

Abstract

Abstract Background Point-of-care transthoracic echocardiography (POC-TTE) is essential in shock management, allowing for stroke volume (SV) and cardiac output (CO) estimation using left ventricular outflow tract diameter (LVOTD) and left ventricular velocity time integral (VTI). Since LVOTD is difficult to obtain and error-prone, the body surface area (BSA) or a modified BSA (mBSA) is sometimes used as a surrogate (LVOTDBSA, LVOTDmBSA). Currently, no models of LVOTD based on patient characteristics exist nor have BSA-based alternatives been validated. Methods Focused rapid echocardiographic evaluations (FREEs) performed in intensive care unit patients over a 3-year period were reviewed. The age, sex, height, and weight were recorded. Human expert measurement of LVOTD (LVOTDHEM) was performed. An epsilon-support vector regression was used to derive a computer model of the predicted LVOTD (LVOTDCM). Training, testing, and validation were completed. Pearson coefficient and Bland-Altman were used to assess correlation and agreement. Results Two hundred eighty-seven TTEs with ideal images of the LVOT were identified. LVOTDCM was the best method of SV measurement, with a correlation of 0.87. LVOTDmBSA and LVOTDBSA had correlations of 0.71 and 0.49 respectively. Root mean square error for LVOTDCM, LVOTDmBSA, and LVOTDBSA respectively were 13.3, 37.0, and 26.4. Bland-Altman for LVOTDCM demonstrated a bias of 5.2. LVOTDCM model was used in a separate validation set of 116 ideal images yielding a linear correlation of 0.83 between SVHEM and SVCM. Bland Altman analysis for SVCM had a bias of 2.3 with limits of agreement (LOAs) of − 24 and 29, a percent error (PE) of 34% and a root mean square error (RMSE) of 13.9. Conclusions A computer model may allow for SV and CO measurement when the LVOTD cannot be assessed. Further study is needed to assess the accuracy of the model in various patient populations and in comparison to the gold standard pulmonary artery catheter. The LVOTDCM is more accurate with less error compared to BSA-based methods, however there is still a percentage error of 33%. BSA should not be used as a surrogate measure of LVOTD. Once validated and improved this model may improve feasibility and allow hemodynamic monitoring via POC-TTE once it is validated.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3