Author:
He Xinjian,Chen Jiaoyang,Li Gaoyang
Abstract
Abstract
Background
The purpose of this study was to explore echocardiographic views and methods of aortic arch anomalies in infants, so as to improve the screening sensitivity and diagnostic accuracy.
Methods
140 children with abnormal aortic arch diagnosed by ultrasound in Children’s Hospital of Hebei Province from January 2014 to December 2019 were selected for retrospective analysis. All were confirmed by surgery or/and computerized tomography angiography. Series of views for aortic arch (the three-vessel and tracheal view, aortic arch short axis view, left aortic arch long axis view, aortic arch long axis continuous scan views) were performed in all cases on the basis of the routine views of echocardiography. The screening sensitivity and diagnostic coincidence rate of different echocardiographic views for aortic arch anomalies were analyzed.
Results
Among the 140 infants, right aortic arch were 21 cases (6/21 were accompanied by mirror branch and 15/21 were with aberrant left subclavian artery). Left aortic arch with aberrant right subclavian artery were 2 cases, and double aortic arch with both arches open were 20 cases. Double aortic arch with left arch atresia were 2 cases, and atresia of the proximal aorta with aortic arch dysplasia was 1 case. Coarctation of the aorta were 67 cases, and interruption of aortic arch were 27 cases. All the patients were correctly diagnosed except that 2 infants with interruption of aortic arch were incorrectly diagnosed as coarctation of the aorta, and 1 infant with coarctation of the aorta was misdiagnosed as interruption of aortic arch by echocardiography. The screening sensitivities of four views and four-view combination for abnormal aortic arch were 99.3, 73.6, 87.1, 99.3, and 100%; the diagnostic coincidence rates were 85.7, 27.1,66.4, 95.0%, and 97.9% respectively. On the basis of traditional left aortic long axis view, other three views had their own advantages. The screening sensitivity and diagnostic coincidence rate of four-view combination were significantly improved.
Conclusions
The three-vessel trachea view is simple and feasible, which is suitable for screening abnormal aortic arch. The combination of four views conduces to improving screening sensitivity and diagnostic accuracy of aortic arch abnormalities.
Funder
Key research and development project of Hebei Province
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献