Quality control of [177Lu]Lu-PSMA preparations using HPLC: effect of sample composition and ligand on recovery

Author:

Aalbersberg Else A.ORCID,Cao Tammie T.,Geluk-Jonker Martine M.,Hendrikx Jeroen J. M. A.

Abstract

Abstract Background [177Lu]Lu-PSMA is used for the treatment of metastatic castration-resistant prostate cancer. For in-house productions, quality control methods are essential for ensuring product quality, and thus patient safety. During HPLC method development for quality control of [177Lu]Lu-PSMA-I&T, we noticed an unpredictable variability in peak area and height with replicate measurements. After a run, irremovable radioactivity was measured over the whole the length of the HPLC column, with slightly higher activity at the beginning and end of the column. The uniform distribution suggests that [177Lu]Lu-PSMA-I&T interacts with the column. As a result of the interaction, incomplete and variable recovery of injected activity was observed leading to the variability in peak area and height. Therefore the aim of this study was to (1) investigate the effect of sample composition on the interaction of [177Lu]Lu-PSMA-I&T to the HPLC column (measured as recovery, peak area, and peak height), and (2) to compare this with same concentrations of the well-known [177Lu]Lu-PSMA-617. Results Sample composition significantly affects recovery of [177Lu]Lu-PSMA-I&T, leading to a change in peak area and height. Recovery was 24% when diluted with 0.1 mM octreotide, 38% with water, and increased to 95% when diluted with 0.7 mM unlabeled PSMA-I&T. Peak area and height decreased to 26% and 17% when diluted in octreotide and to 41% and 29% when diluted in water, compared to a dilution in PSMA-I&T. Further experiments showed that recovery (and consequently peak area and peak height) reached a plateau of > 99% at concentrations of 0.27 mM and higher. [177Lu]Lu-PSMA-617 also interacts with the HPLC column, leading to lower, but less variable, recovery (9%). The low recovery of [177Lu]Lu-PSMA-617 could not be prevented with addition of unlabeled PSMA-617. Conclusion [177Lu]Lu-PSMA-I&T can undergo an irreversible binding with an HPLC column resulting in a decreased recovery. The recovery is can be highly dependent on sample composition. The addition of a surplus of unlabeled PSMA-I&T leads to an accurate analysis of [177Lu]Lu-PSMA-I&T.

Publisher

Springer Science and Business Media LLC

Subject

Pharmacology (medical),Pharmacology,Radiology, Nuclear Medicine and imaging,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Improved quality control of [177Lu]Lu-PSMA I&T;EJNMMI Radiopharmacy and Chemistry;2023-03-27

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3