Investigating the correlation between morphological features of microplastics (5–500 µm) and their analytical recovery

Author:

Hagelskjær O.,Crézé A.,Le Roux G.,Sonke J. E.

Abstract

AbstractAs a direct result of laboratory sample manipulation required to identify microplastics (MPs) within a given matrix, some MPs are inevitably lost. The extent of this loss can be quite significant and varies greatly depending on the sample matrix, choice of protocol and target MPs in question. Defining analytical MP recovery is therefore a critical component in ensuring the quality of MP protocols. The potential relationship between particle size and recovery rate has been widely discussed but remains uncertain. To determine whether MP loss correlated with particle size, three aliquots of polyethylene fragments in the 5–50 µm size range and three aliquots of polypropylene fragments in the 50–500 µm size range, were consecutively transferred back and forth from filter to liquid. After each individual transfer the analytical recovery within specified size groups, was evaluated by applying high-resolution darkfield microscopy. Average recovery across the entire size range was estimated at 80% with a standard deviation (std. dev.) of 26%. Notably, particle coverage on filters (A%) showed a more significant impact on recovery than particle size. Maintaining A% below 5% on filters for microscopic analysis is advised to prevent excessive loss due to particle agglomeration. To determine whether the use of red polyethylene fragments in the 5–50 µm size range in combination with darkfield microscopy could potentially improve MP recovery evaluation in environmental samples, three aliquots of 0.5 g of dry brown trout muscle tissue were spiked and treated according to a relevant protocol. This size-discriminating approach accurately determined average recovery at 52% with a std. dev. of 4% and demonstrated the potential for correction of the concentration enhancement of smaller MPs resulting from particle breakup during sample pre-treatment, which would otherwise lead to overestimation of smaller size fractions.

Funder

Centre National de la Recherche Scientifique

Agence Nationale de la Recherche

Interreg

observatoire Homme-Milieu Pyrénées Haut Vicdessos

Publisher

Springer Science and Business Media LLC

Subject

General Medicine,General Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3