Correlation and agreement between arterial and venous blood gas analysis in patients with hypotension—an emergency department-based cross-sectional study

Author:

Prasad Hari,Vempalli Nagasubramanyam,Agrawal Naman,Ajun U. N.,Salam Ajmal,Subhra Datta Soumya,Singhal Ashutosh,Ranjan Nishant,Shabeeba Sherin P. P.,Sundareshan G.

Abstract

Abstract Background Blood gas analysis is integral to assessing emergency department (ED) patients with acute respiratory or metabolic disease. Arterial blood gas (ABG) is the gold standard for oxygenation, ventilation, and acid–base status but is painful to obtain. Peripheral venous blood gas (VBG) is a valuable alternative as it is less painful and easy to collect. The comparability of ABG and VBG was studied in various conditions. But in hypotension, previous findings were inconsistent. So, we studied the correlation and agreement between ABG and VBG in hypotensive patients. Methodology The study was conducted at the emergency department of a tertiary healthcare center in Northern India. Patients with hypotension above 18 years who satisfied the inclusion criteria were clinically evaluated. Patients who require ABG as a part of routine care were sampled. ABG was collected from the radial artery. VBG was obtained from the cubital or dorsal hand veins. Both samples were collected within 10 min and were analyzed. All ABG and VBG variables were entered in premade proforma. The patient was then treated and disposed of according to institutional protocol. Results A total of 250 patients were enrolled. The mean age was 53.25 ± 15.71 years. 56.8% were male. The study included 45.6% septic, 34.4% hypovolemic, 18% cardiogenic, and 2% obstructive shock patients. The study found a strong correlation and agreement for ABG and VBG pH, pCO2, HCO3, lactate, sodium, potassium, chloride, ionized calcium, blood urea nitrogen, base excess, and arterial/alveolar oxygen ratio. Hence, regression equations were made for the aforementioned. There was no correlation observed between ABG and VBG pO2 and SpO2. Our study concluded that VBG could be a reasonable alternative for ABG in hypotensive patients. We can also mathematically predict values of ABG from VBG using regression equations derived. Conclusions ABG sampling causes most unpleasant experiences to patients and is associated with complications like arterial injury, thrombosis, air or clotted-blood embolism, arterial occlusion, hematoma, aneurysm formation, and reflex sympathetic dystrophy. The study has shown strong correlations and agreements for most ABG and VBG parameters and can predict ABG mathematically using regression formulas formulated from VBG. This will decrease needle stick injury, consume less time, and make blood gas evaluation easy in hypotensive settings.

Publisher

Springer Science and Business Media LLC

Subject

Emergency Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3