Author:
Coentro Viviane Silva,Perrella Sharon Lisa,Lai Ching Tat,Rea Alethea,Murray Kevin,Geddes Donna Tracy
Abstract
Abstract
Background
Concerns about reduced milk transfer with nipple shield (NS) use are based on evidence from studies with methodological flaws. Milk removal during breastfeeding can be impacted by infant and maternal factors other than NS use. The aim of this study was to control electric breast pump vacuum strength, pattern and duration across multiple study sessions to determine if NS use reduces milk removal from the breast.
Methods
A within-subject study with two groups of breastfeeding mothers (infants < 6 months) were recruited; Control Group (CG): no breastfeeding difficulties; Pain Group (PG) used NS for persistent nipple pain. Mothers completed three randomised 15 min pumping sessions using the Symphony vacuum curve (Medela AG); no NS, fitted NS, and a small NS. Sessions were considered valid where the applied vacuum was within 20 mmHg of the set vacuum. Milk removal was considered as pumped milk volume, and also percentage of available milk removed (PAMR), which is calculated as the pumped volume divided by the estimated milk volume stored in the breast immediately prior to pumping.
Results
Of 62 sessions (all: n = 31 paired sessions) a total of 11 paired sessions from both PG (n = 03) and CG (n = 08) were valid (subset) with and without a fitted NS. Only 2 small shield sessions were valid and so all small shield measurements were excluded. Both pumped volumes and PAMR were significantly lower with NS use for all data but not for subset data. (All: Volume and PAMR median: no NS: 76.5 mL, 69%, Fitted NS: 32.1 mL, 41% respectively (volume p = 0.002, PAMR p = 0.002); Subset: Volume and PAMR median: no NS: 83.8 mL, 72%; Fitted NS: 35.2 mL, 40% (volume p = 0.111 and PAMR p = 0.045). The difference in PAMR, but not volume, was statistically significant when analysed by linear mixed modelling. A decrease of 10 mmHg was associated with a 4.4% increase in PAMR (p = 0.017).
Conclusions
This experimental data suggests that nipple shield use may reduce milk removal. Close clinical monitoring of breastfeeding mothers using nipple shields is warranted.
Funder
Science Without Borders, Government of Brazil
Medela
Publisher
Springer Science and Business Media LLC
Subject
Obstetrics and Gynecology
Reference33 articles.
1. Schwartz K, D’Arcy HJ, Gillespie B, Bobo J, Longeway M, Foxman B. Factors associated with weaning in the first 3 months postpartum. J Fam Pract. 2002;51(5):439–44.
2. Riordan J, Bibb D, Miller M, Rawlins T. Predicting breastfeeding duration using the LATCH breastfeeding assessment tool. J Hum Lact. 2001;17(1):20–3.
3. Berens P, Eglash A, Malloy M, Steube AM. ABM Clinical Protocol #26: Persistent Pain with Breastfeeding. Breastfeed Med. 2016;11:46–53.
4. Odom EC, Li R, Scanlon KS, Perrine CG, Grummer-Strawn L. Reasons for earlier than desired cessation of breastfeeding. Pediatrics. 2013;131(3):e726-32.
5. McClellan HL, Hepworth AR, Kent JC, Garbin CP, Williams TM, Hartmann PE, et al. Breastfeeding frequency, milk volume, and duration in mother-infant dyads with persistent nipple pain. Breastfeed Med. 2012;7:275–81.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献