Author:
Mitsuyama Yumi,Katayama Yusuke,Oi Kazuya,Shimazaki Junya,Mimura Kazuya,Endo Masayuki,Shimazu Takeshi
Abstract
Abstract
Introduction
Postpartum haemorrhage is a major cause of maternal mortality. Although contrast-enhanced computed tomography (CE-CT) is useful to reveal arterial bleeding, its accuracy in postpartum haemorrhage is unclear. The aim of this study was to evaluate the accuracy of CE-CT scanning in detecting postpartum haemorrhage.
Methods
This was a retrospective observational study. We included patients with postpartum haemorrhage treated by emergency physicians in collaboration with obstetricians. We calculated the sensitivity, specificity, and positive and negative predictive values for CE-CT scanning to detect arterial bleeding.
Results
CE-CT scanning was performed in 52 patients, and 31 patients had extravasation. The sensitivity of CE-CT scanning to detect arterial extravasation was 100% (15/15), specificity was 28.6% (2/7), positive predictive value was 75% (15/20), and negative predictive value was 100% (2/2).
Conclusion
We showed the sensitivity of CE-CT scanning to detect arterial extravasation in patients with postpartum haemorrhage to be 100%.
Publisher
Springer Science and Business Media LLC
Subject
Obstetrics and Gynecology
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献