A fragmented segment of a central venous catheter caused delayed ventricular fibrillation: a case report

Author:

Takahashi KeiORCID,Arai Takero,Asai Takashi,Okuda Yasuhisa

Abstract

Abstract Background Central venous port systems may be safely used for chemotherapy of patients with cancer, but several complications may occur associated with their use. Case presentation An 83-year-old man with heat stroke was transferred to our emergency department, where he was treated and became able to eat on the same day. He had been fit and healthy, except for colorectomy and chemotherapy using a central venous access port placed in the right upper jugular vein 8 years ago. The next day, he suddenly had ventricular fibrillation. Cardiopulmonary resuscitation was successful. Emergency coronary angiography showed a catheter-like foreign body in the coronary sinus. Physicians failed to remove the foreign body using catheter therapy, and ventricular fibrillation occurred repeatedly. After induction of general anesthesia, the fractured catheter was removed surgically. Postoperative course was uneventful. Conclusions A fragmented segment of a catheter may suddenly cause ventricular fibrillation years later.

Publisher

Springer Science and Business Media LLC

Subject

Anesthesiology and Pain Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3