Abstract
Abstract
Background
Hemodynamic management during anesthesia in liver transplantation for patients with polycystic liver disease (PLD) can be more challenging because of the bleeding and hemodynamic alterations due to the markedly enlarged liver. We hereby report a case of PLD wherein transesophageal echocardiography (TEE) was employed for optimal hemodynamic monitoring during liver transplantation.
Case presentation
A 61-year-old man was scheduled to undergo liver transplantation for massive PLD. Hemodynamic instability was associated with mechanical displacement of the giant cystic liver. TEE results revealed the collapse of the inferior vena cava due to liver displacement. TEE also detected intrathoracic hemorrhage triggered by detachment from the markedly enlarged liver.
Conclusion
TEE is a valuable monitoring tool for sharing information with surgeons and diagnostic modality for finding the source of bleeding in liver transplantation for PLD and may contribute majorly to the quality of perioperative management.
Publisher
Springer Science and Business Media LLC
Subject
Anesthesiology and Pain Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献