Determinants of point-of-care ultrasound lung sliding amplitude in mechanically ventilated patients

Author:

Briganti David N.,Choi Christine E.,Nguyen Julien,Lanks Charles W.ORCID

Abstract

Abstract Background Although lung sliding seen by point-of-care ultrasound (POCUS) is known to be affected to varying degrees by different physiologic and pathologic processes, it is typically only reported qualitatively in the critical care setting. Lung sliding amplitude quantitatively expresses the amount of pleural movement seen by POCUS but its determinants in mechanically ventilated patients are largely unknown. Methods This was a single-center, prospective, observational pilot study examining 40 hemithoraces in 20 adult patients receiving mechanical ventilation. Each subject had lung sliding amplitude measured in both B-mode and by pulsed wave Doppler at their bilateral lung apices and bases. Differences in lung sliding amplitude were correlated with anatomical location (apex vs base) as well as physiologic parameters including positive end expiratory pressure (PEEP), driving pressure, tidal volume and the ratio of arterial partial pressure of oxygen (PaO2) to fraction of inspired oxygen (FiO2). Results POCUS lung sliding amplitude was significantly lower at the lung apex compared to the lung base in both B-mode (3.6 ± 2.0 mm vs 8.6 ± 4.3 mm; p < 0.001) and the pulsed wave Doppler mode (10.3 ± 4.6 cm/s vs 13.9 ± 5.5 cm/s; p < 0.001) corresponding to expected distribution of ventilation to the lung bases. Inter-rater reliability of B-mode measurements was excellent (ICC = 0.91) and distance traversed in B-mode had a significant positive correlation with pleural line velocity (r2 = 0.32; p < 0.001). There was a non-statistically significant trend towards lower lung sliding amplitude for PEEP ≥ 10 cmH2O, as well as for driving pressure ≥ 15 cmH2O in both ultrasound modes. Conclusion POCUS lung sliding amplitude was significantly lower at the lung apex than the lung base in mechanically ventilated patients. This was true when using both B-mode and pulsed wave Doppler. Lung sliding amplitude did not correlate with PEEP, driving pressure, tidal volume or PaO2:FiO2 ratio. Our findings suggest that lung sliding amplitude can be quantified in mechanically ventilated patients in a physiologically predictable way and with high inter-rater reliability. A better understanding of POCUS derived lung sliding amplitude and its determinants may aid in the more accurate diagnosis of lung pathologies, including pneumothorax, and could serve as a means of further reducing radiation exposure and improving outcomes in critically ill patients.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3