Prehospital portable ultrasound for safe and accurate prehospital needle thoracostomy: a pilot educational study

Author:

Dewar Zachary E.ORCID,Ko Stephanie,Rogers Cameron,Oropallo Alexis,Augustine Andrew,Pamula Ankitha,Berry Christopher L.ORCID

Abstract

Abstract Background Simulated needle thoracostomy (NT) using ultrasound may reduce potential injury, increase accuracy, and be as rapid to perform as the traditional landmark technique following a brief educational session. Our objective was to determine if the use of an educational session demonstrating the use of handheld ultrasound to Emergency Medical Services (EMS) staff to facilitate NT was both feasible, and an effective way of increasing the safety and efficacy of this procedure for rural EMS providers. Methods A pre/post-educational intervention on a convenience sample of rural North American EMS paramedics and nurses. Measurement of location and estimated depth of placement of needle thoracostomy with traditional landmark technique was completed and then repeated using handheld ultrasound following a training session on thoracic ultrasound and correct placement of NT. Results A total of 30 EMS practitioners participated. Seven were female (23.3%). There was a higher frequency of dangerous structures underlying the chosen location with the landmark technique 9/60 (15%) compared to the ultrasound technique 1/60 (1.7%) (p = 0.08). Mean time-to-site-selection for the landmark technique was shorter than the ultrasound technique at 10.7 s (range 3.35–45 s) vs. 19.9 s (range 7.8–50 s), respectively (p < 0.001). There was a lower proportion of correct location selection for the landmark technique 40/60 (66.7%) when compared to the ultrasound technique 51/60 (85%) (p = 0.019). With ultrasound, there was less variance between the estimated and measured depth of the pleural space with a mean difference of 0.033 cm (range 0–0.5 cm) when ultrasound was used as compared to a mean difference of 1.0375 cm (range 0–6 cm) for the landmark technique (95% CI for the difference 0.73–1.27 cm; p < 0.001). Conclusions Teaching ultrasound NT was feasible in our cohort. While time-to-site-selection for ultrasound-guided NT took longer than the landmark technique, it increased safe and accurate simulated NT placement with fewer identified potential iatrogenic injuries.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3