Inter-observer and intra-observer variability in ultrasound assessment of gastric content and volume in critically ill patients receiving enteral nutrition

Author:

Ruiz Ávila Héctor AndrésORCID,Espinosa Almanza Carmelo José,Fuentes Barreiro Cindy Yohana

Abstract

Abstract Background The assessment of gastric content and volume using bedside ultrasound (US) has become a useful tool in emergency departments, anesthesiology departments and inpatient wards, as it provides a rapid and dynamic assessment of the gastric content of patients, which, allows making decisions regarding the risk of regurgitation or the need to adjust the strategy used to induce general anesthesia in patients with a full stomach. This assessment consists of two evaluations: a qualitative one, in which the status of the antrum, in terms of gastric content, is classified into three categories (empty, liquid content and full), and a quantitative one, where gastric volume is estimated. The objective of this study was to estimate the intra-observer and inter-observer agreement in ultrasound assessment of gastric content and volume in critically ill patients receiving enteral nutrition. Results A total of 41 patients were included and each examiner performed 64 gastric US (n = 128). Participants’ average age was 56.5 years (SD ± 12.6) and 63.4% were men. Regarding the qualitative evaluation of the antrum, in supine position both examiners classified the gastric content as grade 0 in 1 gastric US (1.5%), grade 1 in 4 gastric US (6.2%) and grade 2 in 59 (92.1%). Regarding intra-observer variability in the measurement of the area of the antrum, Lin's concordance correlation coefficient (CCC), the difference of means between measurements and the 95% limits of agreement of Bland and Altman values were 0.95 (95% CI 0.940–0.977), − 0.47 cm2 (SD ± 1.64) and − 3.70 cm2 to 2.75 cm2, respectively, in EC1, and 0.94 (95% CI 0.922–0.973), − 0.18 cm2 (SD ± 2.18) and − 4.47 cm2 to 4.09 cm2 in EC2. Concerning to inter-observer variability (EC1 vs EC2) in the measurement of the area of the antrum and of gastric volume, the following CCC, mean difference between measurements and 95% limits of agreement of Bland and Altman values were obtained: measurement of the area of the antrum: 0.84 (95% CI 0.778–0.911), − 0.86 cm2 (SD ± 3.38) and − 7.50 cm2 to 5.78 cm2; gastric volume measurement: 0.84 (95% CI 0.782–0.913), − 12.3 mL (SD ± 49.2) and − 108.8 mL to 84.0 mL. Conclusions The assessment of gastric content and volume using bedside US in critically ill patients on mechanical ventilation and receiving enteral nutrition showed a good intra and inter-rater reliability. Most of the patients included in the study had a high risk of pulmonary aspiration, since, according to the results of the gastric US evaluation, they had gastric volumes > 1.5 mL/kg.

Publisher

Springer Science and Business Media LLC

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3