Abstract
Abstract
Background
By combining high-frequency and contrast-enhanced ultrasound (CEUS), the position of the severed end of a finger extensor tendon injury and the injury classification can be determined as part of a comprehensive preoperative evaluation in clinical practice. However, there have been no reports of high-frequency ultrasound combined with CEUS for the preoperative diagnosis of human finger extensor tendon injury.
Cases presentation
One case of complete rupture of the extensor tendon was diagnosed by ultrasound, which was completely consistent with the surgery; one case of incomplete rupture was ultimately confirmed clinically; and one case of distal phalangeal bone base avulsion fracture with tendon contusion and missed diagnosis on the first radiographic examination was confirmed by follow-up radiographic examination.
Conclusions
Different types of finger extensor tendon injuries exhibit distinctive contrast-enhanced ultrasonography findings. Combined high-frequency and contrast-enhanced ultrasound can accurately locate the position of the severed end of the finger extensor tendon injury before surgery while observing the contrast agent filling area to clarify injury classification, providing a reliable imaging basis for clinical practice and ultimately developing personalized diagnosis and treatment plans for patients to ensure minimal trauma and pain, as well as optimal treatment effects.
Funder
Health Commission of Sichuan Province
Publisher
Springer Science and Business Media LLC
Reference9 articles.
1. Du XL, Bi DY, Wang J et al (2020) Spontaneous rupture of extensor pollicis tendon in 7 cases. J practical Hand Surgery 34(3):350–351
2. Liang T, Chen HY, Tu B et al (2021) Application value of ultrasonography in diagnosing spontaneous rupture of finger extensor tendon induced by rheumatoid arthritis. Chin J Ultrasound Med 37(1):81–83
3. Gelberman RH, Amifl D, Gonsalves M et al (1981) The influence of protected passive mobilization on the healing of flexor tendons:a biochemical and microangiographic study. Hand 13(2):120–128
4. Piscaglia F, Nolsoe C, Dietrich CF et al (2012) The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33(1):33–59
5. Tang YQ, Zeng C, Su XT et al (2019) The value of percutaneous shoulder puncture with contrast-enhanced ultrasound in differentiation of rotator cuff tear subtypes: a preliminary prospective study. Ultrasound Med Biol 45(3):660–671