Study on the rationality of small diameter metallic airway stent in treatment of tracheal stenosis in injured rabbits

Author:

Li Xiaoxiao,Wang Changguo,Liu Ziyi,Wu Kai,Yang Zhenyu,Zeng Daxiong,Lin Dang,Jiang Junhong

Abstract

Abstract Background To observe the occurrence of related complications after self-expandable metallic (SEM) airway stents implantation with different diameters at different time points, and to provide theoretical basis for the optimal chioce of existing airway stents in clinical practice. Methods Healthy New Zealand white rabbits were used to establish benign tracheal stenosis models after chest CT examination. Forty-fivemodel rabbits with more than 50% of airway stenosis were divided into two groups. Small-diameter SEM stents (The ratio of stent diameter to airway diameter is nearly 1.0) were implanted in Group A in 21 rabbits, and large-diameter tracheal stents (The ratio of stent diameter to airway diameter is more than 1.2) were implanted in Group B in 24 rabbits. Stent-related complications were observed after stent implantation in 2nd,4th,8th, and 12th week by bronchoscopygross anatomy, pathological and the expressions of IL-1RA, IL-8 and MMP9 in involved tracheal. Results The incidence rate of tracheomalacia of stent was significantly higher in group B (24/24 100%) than that in group A (1 /21,4.8%) (P < 0.05). The incidence rate of scar contracture at both ends of stent was significantly higher than in group B (11 / 24,45.8%) that in group A (2 /21, 9.5%) (P < 0.05). The pathological results of both A and B showed that the columnar epithelium of bronchial mucosa began to damage and detach, inflammatory cells infiltrated after 2nd and 4th week of stenting, The epithelium was repaired, the lamina propria glands almost disappeared, collagen fiber proliferation was obvious, and scars were formed after 8th and 12th week of stenting. ELISA results revealed that the expressions of IL-1RA, IL-8, and MMP9 were increased in the stent group than in model rabbit with benign tracheal stenosis. IL-1RA and MMP9 increased at different periods in group B, but the expression of IL-1RA and MMP9 showed a tread of increasing in the early stage and then decreasing in group A. Conclusion Metal stents can cause different degrees of stent-related complications in rabbits with benign tracheal stenosis. The incidence of stent-induced tracheomalacia and scar contracture were higher in Group B than that in Group A. IL-1RA, IL-8 and MMP9 may be involved in the development of complications after stentimplantation and peak value of group B movered backward. ing.

Publisher

Springer Science and Business Media LLC

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Study on complications after implantation of different types of metal stents in rabbit trachea;International Journal of Pediatric Otorhinolaryngology;2024-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3