Perioperative management and cardiac surgery in pregnant women with anti-phospholipid syndrome combined with heart valve disease have been rarely reported.
Case presentation
We describe a case of transcatheter mitral valve-in-valve replacement in a pregnant woman with bioprosthetic valve failure and anti-phospholipid syndrome at 18 weeks’ gestation. The patient underwent a cesarean section delivery at 34 weeks of gestation, resulting in the birth of a healthy baby.
Conclusions
Transapical mitral valve-in-valve surgery resulted in safe maternal and infant outcomes in a pregnant woman with anti-phospholipid syndrome combined with mitral bioprosthetic valve failure. The success of this procedure underscored the importance of multidisciplinary teamwork.