Does the “obesity paradox” exist after transcatheter aortic valve implantation?

Author:

Luo Zeng-Rong,Chen Liang-wan,Qiu Han-Fan

Abstract

Abstract Background Transcatheter aortic valve implantation (TAVI) for symptomatic aortic stenosis is considered a minimally invasive procedure. Body mass index (BMI) has been rarely evaluated for pulmonary complications after TAVI. This study aimed to assess the influence of BMI on pulmonary complications and other related outcomes after TAVI. Methods The clinical data of 109 patients who underwent TAVI in our hospital from May 2018 to April 2021 were retrospectively analyzed. Patients were divided into three groups according to BMI: low weight (BMI < 21.9 kg/m2, n = 27), middle weight (BMI 21.9–27.0 kg/m2, n = 55), and high weight (BMI > 27.0 kg/m2, n = 27); and two groups according to vascular access: through the femoral artery (TF-TAVI, n = 94) and through the transapical route (TA-TAVI, n = 15). Procedure endpoints, procedure success, and adverse outcomes were evaluated according to the Valve Academic Research Consortium (VARC)-2 definitions. Results High-weight patients had a higher proportion of older (p < 0.001) and previous percutaneous coronary interventions (p = 0.026), a higher percentage of diabetes mellitus (p = 0.026) and frailty (p = 0.032), and lower glomerular filtration rate (p = 0.024). Procedure success was similar among the three groups. The 30-day all-cause mortality of patients with low-, middle-, and high weights was 3.7% (1/27), 5.5% (3/55), and 3.7% (1/27), respectively. In the multivariable analysis, middle- and high-weight patients exhibited similar overall mortality (middle weight vs. low weight, p = 0.500; high weight vs. low weight, p = 0.738) and similar intubation time compared with low-weight patients (9.1 ± 7.3 h vs. 8.9 ± 6.0 h vs. 8.7 ± 4.2 h in high-, middle-, and low-weight patients, respectively, p = 0.872). Although high-weight patients had a lower PaO2/FiO2 ratio than low-weight patients at baseline, transitional extubation, and post extubation 12th hour (p = 0.038, 0.030, 0.043, respectively), there were no differences for post extubation 24th hour, post extubation 48th hour, and post extubation 72nd hour (p = 0.856, 0.896, 0.873, respectively). Chronic lung disease [odds ratio (OR) 8.038, p = 0.001] rather than high weight (OR 2.768, p = 0.235) or middle weight (OR 2.226, p = 0.157) affected postoperative PaO2/FiO2 after TAVI. Conclusions We did not find the existence of an obesity paradox after TAVI. BMI had no effect on postoperative intubation time. Patients with a higher BMI should be treated similarly without the need to deliberately extend the intubation time for TAVI.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3