Mitral valve replacement using a collar-reinforced mitral prosthesis for severe mitral annular calcification, which secures implantation in both the supra-annular and intra-atrial positions: a case report

Author:

Morishita Atsushi,Tomioka Hideyuki,Katahira Seiichiro,Hoshino Takeshi,Hanzawa Kazuhiko

Abstract

Abstract Background Appropriate management of mitral annular calcification associated with mitral valve surgery must be determined on a case-by-case basis. However, an established procedure remains uncertain. Case presentation This report describes a surgical case of severe mitral and aortic valve stenosis associated with severe mitral annular calcification in a 71-year-old woman who underwent mitral valve replacement with a collar-reinforced mitral prosthesis. The patient underwent surgical repair after the treatment for heart failure. As the present patient was deemed to be at high risk for conventional mitral valve replacement, we applied a composite prosthetic valve that was enlarged circumferentially on the ventricular side of the prosthesis with a bovine pericardial patch. First, the solid calcium bar was left untouched and only the friable calcified mass that was easily scattered was removed. Subsequently, the prosthesis was secured by two mattress sutures placed in the intra-atrial position at the region of the extended calcified myocardium. Additionally, ten mattress sutures were placed in the supra-annular position at the other regions capable of passing stitches from the ventricular side to the atrial side. Finally, a 1.5 cm wide trimmed bovine pericardial collar was sutured circumferentially from the annulus to the atrial wall using running 4–0 polypropylene for reinforcement. Although temporary hemodialysis was performed for acute renal failure, the patient remained asymptomatic. Conclusions The present case suggests that mitral valve replacement using a collar-reinforced mitral prosthesis may be an effective technique for severe mitral annular calcification. To avoid catastrophic complications associated with treatment for severely calcified annulus, it is crucial to make a prudent preoperative decision regarding the surgical strategy under circumstances where conventional mitral valve replacement is impossible.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3