Author:
Ala Musu,Liu Junzhong,Kou Jieli,Wang Xinhua,Sun Minfeng,Hao Changcheng,Wu Jianlin
Abstract
Abstract
Objectives
To retrospectively analyse the potential influencing factors of CT-guided hook wire localization failure prior to thoracoscopic resection surgery of ground glass nodules (GGNs), and determine the main risk elements for localization failure.
Methods
In all, 372 patients were included in this study, with 21 patients showing localization failure. The related parameters of patients, GGNs, and localization were analysed through univariate and multiple logistic regression analysis to determine the risk factors of localization failure.
Results
Univariate logistic regression analysis indicated that trans-fissure (odds ratio [OR] 4.896, 95% confidence interval [CI] 1.489–13.939); trans-emphysema (OR 3.538, 95% CI 1.343–8.827); localization time (OR 0.956, 95% CI 0.898–1.019); multi-nodule localization (OR 2.597, 95% CI 1.050–6.361); and pneumothorax (OR 10.326, 95% CI 3.414–44.684) were risk factors for localization failure, and the p-values of these factors were < 0.05. However, according to the results of multivariate analysis, pneumothorax (OR 5.998, 95% CI 1.680–28.342) was an exclusive risk factor for the failure of preoperative localization of GGNs.
Conclusion
CT-guided hook wire localization of GGNs prior to thoracoscopic surgery is often known to fail; however, the incidence is low. Pneumothorax is an independent risk factor for failure in the localization process.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献