Surgery of ascending aorta with complex procedures for aortic dissection through upper mini-sternotomy versus conventional sternotomy

Author:

Wu Yang,Jiang Wei,Li Dong,Chen Lei,Ye Weihua,Ren Chonglei,Xiao Cangsong

Abstract

Abstract Background Use of minimally invasive approaches for isolated aortic valve or ascending aorta surgery is increasing. However, total arch replacement or aortic root repair through a minimally invasive incision is rare. This study was performed to report our initial experience with surgery of the ascending aorta with complex procedures through an upper mini-sternotomy approach. Methods We retrospectively analyzed 80 patients who underwent ascending aorta replacement combined with complex procedures including hemi-arch, total arch, and aortic root surgeries from September 2010 to May 2018. Using standard propensity score-matching analysis, 36 patients were matched and divided into 2 groups: the upper mini-sternotomy group (n = 18) and the median sternotomy group (n = 18). The preoperative assessment revealed no statistically significant differences between the two groups. Results Hospital mortality occurred in one patient (2.8%). The mini-sternotomy group showed a longer cross-clamping time (160 ± 38 vs. 135 ± 36 min, p = 0.048) due to higher rate of valve-sparing aortic root replacement and total arch repair. The cardiopulmonary bypass time in mini-sternotomy group was shorter than that of full sternotomy group (209 ± 47 min vs 218 ± 62 min, p = 0.595) but fell short of significance. There was no significant difference in lower body hypothermia circulatory arrest time between the two groups (40 ± 10 min vs 48 ± 20 min, p = 0.139). The upper mini-sternotomy group displayed a shorter ventilation time (22 vs. 45 h, p = 0.014), intensive care unit stay (4.6 ± 2.7 vs. 7.9 ± 3.7 days, p = 0.005), and hospital stay (8.2 ± 3.8 vs. 21.4 ± 11.9 days, p = 0.001). The upper mini-sternotomy group showed a lower postoperative red blood cell transfusion volume (4.6 ± 3.3 vs. 6.7 ± 5.7 units, p = 0.042) and postoperative drainage volume (764 ± 549 vs. 1255 ± 745 ml, p = 0.034). The rates of dialysis for newly occurring renal failure, neurological complications, and re-exploration were similar between the two groups (p = 1.000). Conclusion The upper mini-sternotomy approach is safe and beneficial in ascending aorta surgery with complex procedures for aortic dissection, including total arch replacement and aortic root repair.

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3