Author:
Yao Jian,Bai Tao,Yang Bo,Sun Lizhong
Abstract
Abstract
Objective
This study aims to evaluate the diagnostic value of D-dimer for acute aortic dissection (AAD) by the method of meta-analysis.
Methods
PubMed, Cochrane Library, Web of Science, Embase, China National Knowledge Infrastructure (CNKI), and Wanfang databases from the establishment of the databases to December 2020 were systematically searched, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) system was used to evaluate the quality of the literature. STATA 15.0 software was applied to calculate the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (+LR), negative likelihood ratio (−LR) to draw summary receiver operating characteristics (SROC) curve and calculate the area under the curve (AUC). Meta-regression and subgroup analyses were used to explore the source of heterogeneity.
Results
A total of 16 clinical studies were enrolled in this study, including 1135 patients. The results of the meta-analysis showed that the pooled sensitivity was 0.96 (95% CI 0.91–0.98), the pooled specificity was 0.70 (95% CI 0.57–0.81), and the pooled DOR was 56.57 (95% CI 25.11–127.44), the pooled +LR was 3.25 (95% CI 2.18–4.85), the pooled −LR was 0.06 (95% CI 0.03–0.12), and the AUC was 0.94 (95% CI 0.91–0.95). Meta-regression and subgroup analysis results showed that publication year, sample size and cutoff value might be sources of heterogeneity. When the concentration of D-dimer was less than or equal to 500 ng/ml, the sensitivity significantly increased.
Conclusion
D-dimer has an excellent diagnostic value for AAD. It is a useful tool for detecting suspected AAD because of the excellent pooled sensitivity. D-dimer ≤ 500 ng/ml increases the potential to identify the suspected patients with AAD.
Publisher
Springer Science and Business Media LLC
Subject
Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine
Reference48 articles.
1. Gohbara M, Endo T, Kimura K, Tamura K. Left main trunk stenting in a case of acute aortic dissection: a case report. Clin Case Rep. 2017;5(10):1649–53.
2. Howard DP, Banerjee A, Fairhead JF, Perkins J, Silver LE, Rothwell PM. Population-based study of incidence and outcome of acute aortic dissection and premorbid risk factor control: 10-year results from the Oxford Vascular Study. Circulation. 2013;127(20):2031–7.
3. Davies RR, Goldstein LJ, Coady MA, et al. Yearly rupture or dissection rates for thoracic aortic aneurysms: simple prediction based on size. Ann Thorac Surg. 2002;73(1):17–27.
4. Weber T, Auer J, Eber B, Nienaber CA, Eagle KA. Value of d-dimer testing in acute aortic dissection. Circulation. 2004;109(3):E24.
5. Setacci F, Sirignano P, de Donato G, Chisci E, Perulli A, Setacci C. Acute aortic dissection: natural history and classification. J Cardiovasc Surg. 2010;51(5):641–6.
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献