Preliminary evaluation of autologous pericardium ring for tricuspid Annuloplasty: a two-year follow-up study

Author:

Jiang Wei,Long Xiao-MaoORCID,Li Si-Cong,Zhong Yong-Long,He Bang-Fu,Lin Hui

Abstract

Abstract Objective To evaluate the effectiveness of autologous pericardium ring in tricuspid annuloplasty surgery for the treatment of tricuspid regurgitation (TR). Methods From December 2010 to December 2012, a total of 107 patients with secondary TR underwent tricuspid annuloplasty. The patients were divided into three groups: autologous pericardium ring group (n = 38), Edwards-MC3 ring group (n = 35), and DeVega group (n = 34). The patients were followed-up for two years. The survival rates and free from hospital readmission rates were measured and analyzed. The patients also received transthoracic echocardiography (TTE) in order to obtain TR regurgitant jet area to right atrial area (STR/STA), diastolic tricuspid annuloplasty diameter (DTAD), right atrial diameter (RAD), and right ventricular diameter (RVD). Results One patient from DeVega group and one patient from autologous pericardium ring died from low cardiac output syndrome during the perioperative period. In the two-year follow-up period, each group has one instance of death for unclear reasons. One month after operation, the STR/STA, DTAD, RAD, and RVD values in all groups were significantly lower than the pre-operation values (P < 0.05). During the two year follow-up period, DTAD values of patients from DeVega group increased significantly as compared to the values at one month post operation (P<0.05), which is different from the other two groups in which DTAD values remained stable (P>0.05). In both pericardium ring group and Edwards-MC3 group, STR/SRA, remained stable (P>0.05) during the follow-up period, whereas STR/SRA of the DeVega group had showed a tendency of increase (although statistically insignificant, P>0.05). There was no significant difference in the survival rates among three study groups (P > 0.05), but the rate of free from hospital readmission in the DeVega group was significantly lower than those in the other two groups (P < 0.05) during the two-year follow-up period. Conclusions Autologous pericardium tissue based ring annuloplasty demonstrated remarkable clinical utility for treating tricuspid regurgitation. It shows similar beneficial results to Edwards-MC3 annuloplasty within a short-term follow-up period, and outperforms the widely used DeVega annuloplasty. Autologous pericardium tissue annuloplasty represents a promising technique for tricuspid annuloplasty and holds great potential for treating tricuspid valve dysfunctions.

Funder

Natural Science Foundation of Guangxi Province

Publisher

Springer Science and Business Media LLC

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3