Navigation and non-navigation CT scan of the sinuses: comparison of the effective doses of radiation in children and adults

Author:

Villemure-Poliquin NoémieORCID,Chrétien Mario,Leclerc Jacques E.

Abstract

Abstract Background The advent of 3D navigation imaging has opened new borders to the endoscopic surgical approaches of naso-sinusal inflammatory and neoplastic disease. This technology has gained in popularity among otolaryngologists for endoscopic sinus and skull base surgeries in both adults and children. However, the increased tissue radiation required for data acquisition associated with 3D navigation protocols CT scans is a source of concern because of its potential health hazards. We aimed to compare the effective doses of radiation between 3D navigation protocols and standard protocols for sinus computed tomography (CT) scans for both the adult and pediatric population. Methods We performed a retrospective cohort study through electronic chart review of patients undergoing sinus CT scans (standard and 3D navigation protocols) from May 2019 to December 2019 using a Siemens Drive (VA62A) CT scanner. The effective dose of radiation was calculated in mSv for all exams. Average irradiation doses were compared using a Student’s T-Test or a Kruskall–Wallis test when appropriate. Results A total of 115 CT scans were selected for analysis, of which 47 were standard protocols and 68 were 3D navigation protocols CT scans. Among these, 31 exams were performed on children and 84 exams on adults. For the total population, mean effective dose in the non-navigation CT scans was 0.37 mSv (SD: 0.16, N = 47) and mean effective dose in the 3D navigation sinus CT group was 2.33 mSv (SD: 0.45, N = 68). The mean difference between the two groups was statistically significant 1.97 mSv (CI 95% − 2.1 to − 1.83; P < 0.0001). There was a sixfold increase in radiation with utilization of 3D navigation protocols. The ratio was identical when the pediatric as well as the adult subset of patients were analyzed. Conclusion In our center, utilization of 3D navigation sinus CT protocols significantly increases radiation exposure. Otolaryngologists should be aware of this significant increase and should attempt to decrease the radiation exposure of their patients by limiting unnecessary scan orders and by evaluating 3D acquisition protocols locally with radiation physicists. Level of evidence: Level IV. Graphical Abstract

Publisher

Springer Science and Business Media LLC

Subject

Otorhinolaryngology,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3