Comparison of dislocation rates of Teflon and Titanium stapes prostheses: A retrospective survival analysis on 855 patients

Author:

Gargula Stéphane1ORCID,Daval Mary1,Lecoeuvre Adrien2,Ayache Denis1

Affiliation:

1. Department of Otolaryngology, Hôpital Fondation Adolphe de Rothschild, 29 Rue Manin, 75019, Paris, France

2. Clinical Research Unit, Hôpital Fondation Adolphe de Rothschild, 29 Rue Manin, 75019, Paris, France

Abstract

Background Stapes prosthesis dislocation is the first cause of revision stapes surgery. To our knowledge, there is no data about stability of the incus attachment of manual crimped prosthesis of different materials. This study aimed to compare the dislocation incidence between titanium and fluoroplastic stapes prostheses. Method A monocentric retrospective cohort study was conducted between January 2013 and June 2022 in a tertiary-care center. All patients that underwent a primary stapes surgery with manually crimped fluoroplastic or titanium prostheses were included. Prosthesis dislocation from the incus was identified intraoperatively or with CT scan. The incidence of stapedial prosthesis dislocation over time was estimated using the Kalbfleisch and Prentice survival analysis method. Other indications for revision surgery prior to prosthesis dislocation were considered as competing events. Differences in the cumulative incidence functions between the fluoroplastic group and the titanium group was assessed using the Gray's test. Results Eight hundred and fifty-five patients underwent primary stapes surgery during the study period. Fluoroplastic prosthesis was used in 758 (88.7%) cases and titanium prosthesis in 97 (11.3%) cases. Median follow-up was 51.7 months (28.4–80.1). Dislocation was observed in 23 (3.0%) patients with fluoroplastic prosthesis and none (0.0%) in the titanium group. The probability of prosthesis dislocation at two years after surgery was 3.5% in the Teflon group and 0.0% in the Titanium group. No significant difference was found in the cumulative incidence of prosthesis dislocation between the fluoroplastic group and the titanium group (p = 0.12). Conclusions Despite lack of statistical power, our results suggest a trend in a more stable incus attachment of manually crimped titanium stapes prosthesis compared to fluoroplastic over time. Further prospective randomized studies could be valuable to assess our findings. Graphical Abstract

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3