Risk of magnetic resonance imaging-induced magnet dislocation for different types of cochlear implants: A single-center retrospective study

Author:

Rupp Robin1ORCID,Balk Matthias1,Sievert Matti1,Leibl Victoria1,Schleder Stephan2,Allner Moritz1,Iro Heinrich1,Hoppe Ulrich1,Hornung Joachim1,Gostian Antoniu-Oreste1

Affiliation:

1. Department of Otorhinolaryngology, Head and Neck Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Waldstraße 1, 91054, Erlangen, Germany

2. Department of Diagnostic and Interventional Radiology, Merciful Brothers Hospital St. Elisabeth, 94315, Straubing, Germany

Abstract

Background When performing magnetic resonance imaging (MRI) in patients with a cochlear implant (CI), complication rates vary widely in the literature. The primary objective of this retrospective study was to determine the prevalence of complications, in particular magnet dislocation, in patients with CI undergoing 1.5 Tesla (T) MRI. As a secondary objective, the prevalence of magnet dislocation for specific cochlear implant device types was elaborated. Methods In a single-center retrospective study, all patients with a cochlear implant presenting for an MRI examination at 1.5 T at our institution between January 1st, 2010 and December 31st, 2020 were included. Implants with axial and diametrical magnets were included in the study. MRI safety measures were applied before imaging. The prevalence of complications was evaluated. Magnet dislocation rates were calculated for device types with at least 20 MRI exposures. Results During the study period, 196 MRI examinations were performed in a total of 128 patients, accounting for 149 different implants (21 implanted bilaterally) with a total of 231 implant exposures to MRI (average 1.69 ± 1.57; min. 1, max. 12). Complications were reported in 50 out of 231 cochlear implant exposures (21.6%). Magnet dislocation occurred in a total of 27 cases (11.7%). Dislocation rates were 29.6% for the Cochlear® CI500 series (24 dislocations from 81 exposures), 1.1% for the Cochlear® CI24RE series (1 from 87) and 0% for the MED-EL® Synchrony (0 from 36). The dislocation rate for the CI500 was significantly higher than for the CI24RE (χ2 (1) = 26.86; p < 0.001; ϕ = 0.40) or the Synchrony (χ2 (1) = 13.42; p < 0.001; ϕ = 0.34). Conclusions For 1.5 T MRI, the risk of magnet dislocation ranges from 0 to 29.6% and depends on the CI device type. Implants with a diametrical magnet can be considered potentially MRI-safe, whereas in CIs with axial magnets, the CI500 is at high risk of magnet dislocation. Therefore, apart from a strict indication for an MRI and adherence to safety protocols, post-MRI follow-up examination to rule out magnet dislocation is recommended. Graphical Abstract

Funder

Friedrich-Alexander-Universität Erlangen-Nürnberg

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

Reference30 articles.

1. A review of the safety of MRI in cochlear implant patients with retained magnets

2. Cochlear™ Nucleus® Implants Magnetic Resonance Imaging (MRI) guidelines for Europe, Middle East, Africa. https://mss-p-007-delivery.sitecorecontenthub.cloud/api/public/content/d778af919bf54201bf756d07790bee89?v=72e5f19b. Accessed 26 October 2022.

3. MRT-Sicherheitsinformationen für Cochlea-Implantate von Advanced Bionics, Deutschland. https://www.advancedbionics.com/de/de/home/professionals/mri-safety-information.html. Accessed 26 October 2022.

4. Performing MRI Scans on Cochlear Implant and Auditory Brainstem Implant Recipients: Review of 14.5 Years Experience

5. Cochlear implant magnet dislocation after MRI: surgical management and outcome

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3