Author:
Ruiz Díaz Miguel A., ,Egea García Marta,Muñoz Aguilera Roberto,Viñolas Prat Xavier,Silvestre García Jorge,Álvarez Orozco María,Martínez Ferrer José
Abstract
Abstract
Background
Remote monitoring of cardiac implantable electronic devices (CIEDs) has demonstrated substantial benefits. Treatment guidelines have therefore endorsed its use and is being increasingly adopted in the clinical setting, but the level of satisfaction they convey remains still unknown. We developed and validated a questionnaire to measure patient satisfaction with remote monitoring using Medtronic CareLink® Network and assessed its internal reliability and dimensional validity.
Methods
After a thorough literature review, cognitive debriefing of 18 patients, and an expert panel discussion, a 30-item instrument was proposed and grouped into 5 dimensions (items): 1- Information on cardiac condition (3), 2- Device convenience (3), 3- Transmission process (6), 4- Satisfaction with medical monitoring (8), and 5- General opinions (10). Correlation with the visual analog scale (VAS), overall health related quality of life (HRQoL) measured by the EuroQoL-5D accompanied by the VAS as well as with the Medical Outcomes Study (MOS) SF-36 were assessed. Psychometric properties, exploratory factor analysis and a second order confirmatory factor analysis (a hierarchical CFA with a general common factor explaining the relations between the first order common factors, See Figure 1) were estimated. Models were assessed based on item loading size, sign and statistical significance, and goodness-of-fit statistics.
Results
A total of 186 patients (77% male) with a mean age of 66.03 (SD = 13.94) years were assessed. 48% had implantable cardioverter-defibrillators, 24% had pacemakers, and 29% had cardiac resynchronization therapy devices. An overall Cronbach’s α = 0.893 was achieved, with acceptable reliabilities for isolated dimensions. Correlations with corresponding VAS scales were meaningful and significant (p < 0.01). The second order factor solution yielded good goodness-of-fit indexes (χ2/df = 1.44, CFI = 0.96, TLI = 0.95, RMSEA = 0.05). Satisfaction with remote monitoring was not related to HRQoL (r < 0.05), except for the correlation between the SF-36 mental component and the information on cardiac condition dimension (r = 0.263, p < 0.001).
Conclusions
The 30-item questionnaire showed good reliability and validity to assess satisfaction with remote monitoring in patients with CIEDs.
Publisher
Springer Science and Business Media LLC
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献