Aims
We aimed to conduct a clinical process cost analysis to evaluate all upcoming costs of mitral valve transcatheter edge-to-edge repair (M-TEER) treatment using the MitraClip and the PASCAL repair system.
Methods
First, we prospectively enrolled 107 M-TEER patients treated with either the PASCAL or MitraClip system and compared all upcoming costs during the M-TEER procedure and the associated in-hospital stay. Second, we retrospectively analysed 716 M-TEER procedures with regard to the occurrence of complications and their associated costs. All materials used in the catheterization laboratory for the procedures were evaluated. The cost analysis considered various expenses, such as general in-hospital costs, device costs, catheter laboratory and material costs.
Results
In the prospective study, 51 patients were treated using the PASCAL system, and 56 were treated using the MitraClip system. The two groups had comparable baseline characteristics and comorbidities. The total in-hospital costs were 25 414 (Interquartile range (IQR) 24 631, 27 697) € in the PASCAL group and 25 633 (IQR 24 752, 28 256) € in the MitraClip group (p = 0.515). The major cost driver was initial material expenditure, mostly triggered by device costs, which were similar to the PASCAL and MitraClip systems. Overall intensive care unit and general ward costs did not differ between the PASCAL and MitraClip groups. In the retrospective analysis, M-TEER-related complications were rare but were associated with higher costs, mainly due to prolonged hospitalisation.
Conclusion
The major cost driver of M-TEER was the material expenditure, which was mostly triggered by high device costs. The costs of treating patients were similar for the PASCAL and MitraClip systems. M-TEER-related complications are associated with higher costs, mainly due to prolonged hospitalisation. This analysis provides valuable insights into reducing expenses by modifying the process of M-TEER.
Funder
Edwards Lifesciences
Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts
Publisher
Springer Science and Business Media LLC
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献