Transcranial Doppler as a screening test to exclude intracranial hypertension in brain-injured patients: the IMPRESSIT-2 prospective multicenter international study

Author:

Rasulo Frank A.,Calza Stefano,Robba Chiara,Taccone Fabio Silvio,Biasucci Daniele G.,Badenes Rafael,Piva Simone,Savo Davide,Citerio Giuseppe,Dibu Jamil R.,Curto Francesco,Merciadri Martina,Gritti Paolo,Fassini Paola,Park Soojin,Lamperti Massimo,Bouzat Pierre,Malacarne Paolo,Chieregato Arturo,Bertuetti Rita,Aspide Raffaele,Cantoni Alfredo,McCredie Victoria,Guadrini Lucrezia,Latronico Nicola

Abstract

Abstract Background Alternative noninvasive methods capable of excluding intracranial hypertension through use of transcranial Doppler (ICPtcd) in situations where invasive methods cannot be used or are not available would be useful during the management of acutely brain-injured patients. The objective of this study was to determine whether ICPtcd can be considered a reliable screening test compared to the reference standard method, invasive ICP monitoring (ICPi), in excluding the presence of intracranial hypertension. Methods This was a prospective, international, multicenter, unblinded, diagnostic accuracy study comparing the index test (ICPtcd) with a reference standard (ICPi), defined as the best available method for establishing the presence or absence of the condition of interest (i.e., intracranial hypertension). Acute brain-injured patients pertaining to one of four categories: traumatic brain injury (TBI), subarachnoid hemorrhage (SAH), intracerebral hemorrhage (ICH) or ischemic stroke (IS) requiring ICPi monitoring, were enrolled in 16 international intensive care units. ICPi measurements (reference test) were compared to simultaneous ICPtcd measurements (index test) at three different timepoints: before, immediately after and 2 to 3 h following ICPi catheter insertion. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated at three different ICPi thresholds (> 20, > 22 and > 25 mmHg) to assess ICPtcd as a bedside real-practice screening method. A receiver operating characteristic (ROC) curve analysis with the area under the curve (AUC) was used to evaluate the discriminative accuracy and predictive capability of ICPtcd. Results Two hundred and sixty-two patients were recruited for final analysis. Intracranial hypertension (> 22 mmHg) occurred in 87 patients (33.2%). The total number of paired comparisons between ICPtcd and ICPi was 687. The NPV was elevated (ICP > 20 mmHg = 91.3%, > 22 mmHg = 95.6%, > 25 mmHg = 98.6%), indicating high discriminant accuracy of ICPtcd in excluding intracranial hypertension. Concordance correlation between ICPtcd and ICPi was 33.3% (95% CI 25.6–40.5%), and Bland–Altman showed a mean bias of -3.3 mmHg. The optimal ICPtcd threshold for ruling out intracranial hypertension was 20.5 mmHg, corresponding to a sensitivity of 70% (95% CI 40.7–92.6%) and a specificity of 72% (95% CI 51.9–94.0%) with an AUC of 76% (95% CI 65.6–85.5%). Conclusions and relevance ICPtcd has a high NPV in ruling out intracranial hypertension and may be useful to clinicians in situations where invasive methods cannot be used or not available. Trial registrationNCT02322970.

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3