Lower versus higher hemoglobin threshold for transfusion in ARDS patients with and without ECMO

Author:

Hunsicker O.ORCID,Materne L.ORCID,Bünger V.ORCID,Krannich A.ORCID,Balzer F.ORCID,Spies C.ORCID,Francis R. C.ORCID,Weber-Carstens S.ORCID,Menk M.ORCID,Graw J. A.ORCID

Abstract

Abstract Background Efficacy and safety of different hemoglobin thresholds for transfusion of red blood cells (RBCs) in adults with an acute respiratory distress syndrome (ARDS) are unknown. We therefore assessed the effect of two transfusion thresholds on short-term outcome in patients with ARDS. Methods Patients who received transfusions of RBCs were identified from a cohort of 1044 ARDS patients. After propensity score matching, patients transfused at a hemoglobin concentration of 8 g/dl or less (lower-threshold) were compared to patients transfused at a hemoglobin concentration of 10 g/dl or less (higher-threshold). The primary endpoint was 28-day mortality. Secondary endpoints included ECMO-free, ventilator-free, sedation-free, and organ dysfunction-free composites. Measurements and main results One hundred ninety-two patients were eligible for analysis of the matched cohort. Patients in the lower-threshold group had similar baseline characteristics and hemoglobin levels at ARDS onset but received fewer RBC units and had lower hemoglobin levels compared with the higher-threshold group during the course on the ICU (9.1 [IQR, 8.7–9.7] vs. 10.4 [10–11] g/dl, P < 0.001). There was no difference in 28-day mortality between the lower-threshold group compared with the higher-threshold group (hazard ratio, 0.94 [95%-CI, 0.59–1.48], P = 0.78). Within 28 days, 36.5% (95%-CI, 27.0–46.9) of the patients in the lower-threshold group compared with 39.5% (29.9–50.1) of the patients in the higher-threshold group had died. While there were no differences in ECMO-free, sedation-free, and organ dysfunction-free composites, the chance for successful weaning from mechanical ventilation within 28 days after ARDS onset was lower in the lower-threshold group (subdistribution hazard ratio, 0.36 [95%-CI, 0.15–0.86], P = 0.02). Conclusions Transfusion at a hemoglobin concentration of 8 g/dl, as compared with a hemoglobin concentration of 10 g/dl, was not associated with an increase in 28-day mortality in adults with ARDS. However, a transfusion at a hemoglobin concentration of 8 g/dl was associated with a lower chance for successful weaning from the ventilator during the first 28 days after ARDS onset. Trial Registration: ClinicalTrials.gov NCT03871166.

Funder

Projekt DEAL

Publisher

Springer Science and Business Media LLC

Subject

Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3