Abstract
AbstractIntroductionBrain multimodal monitoring including intracranial pressure (ICP) and brain tissue oxygen pressure (PbtO2) is more accurate than ICP alone in detecting cerebral hypoperfusion after traumatic brain injury (TBI). No data are available for the predictive role of a dynamic hyperoxia test in brain-injured patients from diverse etiology.AimTo examine the accuracy of ICP, PbtO2and the oxygen ratio (OxR) in detecting regional cerebral hypoperfusion, assessed using perfusion cerebral computed tomography (CTP) in patients with acute brain injury.MethodsSingle-center study including patients with TBI, subarachnoid hemorrhage (SAH) and intracranial hemorrhage (ICH) undergoing cerebral blood flow (CBF) measurements using CTP, concomitantly to ICP and PbtO2monitoring. Before CTP, FiO2was increased directly from baseline to 100% for a period of 20 min under stable conditions to test the PbtO2catheter, as a standard of care. Cerebral monitoring data were recorded and samples were taken, allowing the measurement of arterial oxygen pressure (PaO2) and PbtO2at FiO2100% as well as calculation of OxR (= ΔPbtO2/ΔPaO2). Regional CBF (rCBF) was measured using CTP in the tissue area around intracranial monitoring by an independent radiologist, who was blind to the PbtO2values. The accuracy of different monitoring tools to predict cerebral hypoperfusion (i.e., CBF < 35 mL/100 g × min) was assessed using area under the receiver-operating characteristic curves (AUCs).ResultsEighty-seven CTPs were performed in 53 patients (median age 52 [41–63] years—TBI,n = 17; SAH,n = 29; ICH,n = 7). Cerebral hypoperfusion was observed in 56 (64%) CTPs: ICP, PbtO2and OxR were significantly different between CTP with and without hypoperfusion. Also, rCBF was correlated with ICP (r = − 0.27;p = 0.01), PbtO2(r = 0.36;p < 0.01) and OxR (r = 0.57;p < 0.01). Compared with ICP alone (AUC = 0.65 [95% CI, 0.53–0.76]), monitoring ICP + PbO2(AUC = 0.78 [0.68–0.87]) or ICP + PbtO2 + OxR (AUC = 0.80 (0.70–0.91) was significantly more accurate in predicting cerebral hypoperfusion. The accuracy was not significantly different among different etiologies of brain injury.ConclusionsThe combination of ICP and PbtO2monitoring provides a better detection of cerebral hypoperfusion than ICP alone in patients with acute brain injury. The use of dynamic hyperoxia test could not significantly increase the diagnostic accuracy.
Publisher
Springer Science and Business Media LLC
Subject
Critical Care and Intensive Care Medicine
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献