Development, validation and greenness assessment of a new electro-driven separation method for simultaneous analysis of cefixime trihydrate and linezolid in their fixed dose combination

Author:

Habeeb Maha R.,Morshedy Samir M.,Daabees Hoda G.,Elonsy Sohila M.

Abstract

AbstractThe establishment and validation of a straightforward, accurate, and eco-friendly capillary zone electrophoretic-diode array detection (CZE-DAD) procedure has been presented for concurrent measurement of two common antibiotics, namely, linezolid (LIN) and cefixime trihydrate (CEF), in their binary mixture or combined dosage form. The selected fused silica capillary has total and effective lengths equal to 58.5 cm and 50 cm, respectively, with a 50 µm internal diameter. Injections were performed utilizing 100 mM borate buffer at pH 10.2 as the background electrolyte (BGE) with a 15.0 s injection time. The finally utilized voltage was 30 kV. DAD was programmed to measure LIN at 250 nm and CEF at 285 nm. In less than 6 min, the two cited drugs were resolved at 2.51 and 5.47 min for LIN and CEF respectively. The introduced procedure had a linear response in the concentration range of 5–50 μg/mL for both analytes with correlation coefficients > 0.9999. Detection and quantification limits were 1.213 and 4.042 μg/mL, respectively, for LIN and 0.301 and 1.004 μg/mL, respectively, for CEF. Validation was conducted according to the International Council for Harmonization (ICH), concerning linearity, detection and quantitation limits, range, accuracy, precision, selectivity, and robustness. Precision was found acceptable due to the low relative standard deviation (RSD%) values that did not exceed 1.86% either for repeatability or for intermediate precision. Additionally, the adequately recovered concentrations and the low values of percentage relative error (Er%) provide evidence of the accuracy of the proposed method. On the other hand, the robustness of the introduced method was affirmed by the acceptable RSD% values that did not exceed 0.6% after deliberate changes in the following procedure parameters: buffer concentration, buffer pH, and wavelength. Finally, the ability of the presented method to quantify the two tested drugs in laboratory-prepared tablets was confirmed by the adequate recoveries (≥ 99%) utilizing the standard-addition procedure, along with the absence of any significant difference between the proposed method and the reference method as proven by the student’s t-test and the variance-ratio F-test values that did not exceed the theoretical ones. The analytical Eco-Scale and the analytical GREEness metric (AGREE) were the tools utilized for greenness assessment. This CZE procedure is the first electro-driven separation method that was utilized for the analysis of both antibiotics in their combined laboratory-prepared tablets with no interference from the co-formulated adjuvants.

Funder

Damanhour University

Publisher

Springer Science and Business Media LLC

Subject

General Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3