Increased [68Ga]Ga-SST uptake in the uncinate pancreatic process in new digital PET/CT machine and potential association with clinical and histologic factors in NET patients

Author:

Firsova Maria,Treglia Giorgio,Sempoux Christine,Dromain Clarisse,Prior John O.,Schaefer Niklaus,Boughdad SarahORCID

Abstract

Abstract Introduction A physiological increase in the uptake of [68Ga]Ga-labeled somatostatin analogues ([68Ga]Ga-SST) PET tracers has been reported in the uncinate pancreatic process (UP) and might be even higher in latest generation of PET/CT scanners and might be falsely interpreted as NET. We aimed to investigate the uptake of UP in a large population of NET patients who underwent [68Ga]Ga-SST PET/CT with digital SiPM detectors. We also explored potential associations between UP uptake and various clinical, imaging, and pathological factors routinely assessed in NET patients. Methods We analyzed all consecutive NET patients from July 2018 to June 2022 in this retrospective, single-center study. All patients underwent a [68Ga]Ga-SST PET/CT scan on a digital SiPM PET/CT scanner. On visual analysis, we distinguished between normal linear and homogenous UP uptake or abnormal if otherwise. We compared SUVmax/mean in patients with normal UP uptake to those with abnormal UP uptake with suspicious NET lesions on contrast-enhanced CT (ce-CT) and according to the site of the primary NET (pancreatic NET vs. other), patient gender (female vs. male) and tumor grade (grade 1–2 vs. 3) using a Mann–Whitney test. We also assessed the correlation between SUVmax/mean values in UP with patients’ age, primary NET Ki-67 counting, and its SUVmax/mean, TLA and MTV values. Results We included 131 NET patients with a total of 34 [68Ga]Ga-DOTATATE PET/CT and 113 [68Ga]Ga-DOTATOC PET/CT scans. An abnormal UP uptake was seen in 32 patients with 65.7% of suspicious NET lesion or extrinsic compression on morphological imaging. Normal UP uptake SUVmax/mean were measured in 115 [68Ga]Ga-SST scans (78.2%) with normal UP uptake and without suspicious lesion on morphological imaging. We found an average SUVmax of 12.3 ± 4.1 for [68Ga]Ga-DOTATATE and 19.8 ± 9.8 g/ml for [68Ga]Ga-DOTATOC, hence higher than those reported in the literature [SUVmax 5 ± 1.6 to 12.6 ± 2.2 g/ml] with significant difference with abnormal UP uptake and between both PET tracers (both p < 0.01). Significant results were a higher UP uptake on [68Ga]Ga-DOTATOC in male patients (p = 0.02) and significant associations between UP uptake on [68Ga]Ga-DOTATOC and SUVmax/mean of the primary tumor (ρ [0.337–0.363]; p [0.01–0.02]). Conclusion We confirmed a higher and very frequent UP uptake in latest SiPM-detector [68Ga]Ga-SST PET/CT with an even higher uptake in patients that had [68Ga]Ga-DOTATOC PET/CT. SUVmean/max were significantly higher in abnormal UP uptake but there were overlaps with UP SUV values for both [68Ga]Ga-SST and a correlation to morphological imaging is crucial. Besides, significant associations between UP uptake and SUVmean/max of the primary NET as well as patients’ gender were seen in the larger cohort of [68Ga]Ga-DOTATOC patients suggesting that both physiological and pathological parameters could affect UP uptake.

Funder

University of Lausanne

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3