Author:
Babaei Ali Akbar,Azadi Roza,Jaafarzadeh Nemat,Alavi Nadali
Abstract
Abstract
The lab-scale upflow anaerobic biofilm reactor was successfully operated for the treatment of synthetic wastewater with high nitrogen load by Anammox (anaerobic ammonium oxidation) process. During the entire period of operation, the reactor temperature was kept at 35±1°C. The operational strategy consisted of both increasing the ammonium and nitrite concentrations from 60 to 700mgN/L and from 80 to 920 mgN/L, respectively and decreasing the hydraulic retention time from 24 to 6 h, at each step. The highest achieved removal efficiency of ammonium and nitrite were 91 and 93%, respectively. Consequently, due to their acceptable performance for nitrogen removal in previous researches, modified Stover-Kincannon and Grau second-order models were used in this study. According to the experiment results, the model validity testing showed that the Stover-Kincannon model was a little more appropriate for the description of nitrogen removal in the reactor, even though both models gave high correlation coefficients (R2=0.999).
Publisher
Springer Science and Business Media LLC
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health,Waste Management and Disposal,Water Science and Technology,Environmental Engineering
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献