Plethysmographic variability index as a tool to assess fluid responsiveness in critically ill patients: a correlation study with inferior vena cava distensibility index

Author:

Bedi Parvinder Singh,Pahwa Bhavna,Hooda Bhavna,Dwivedi Deepak

Abstract

Background: In critically ill patients in the intensive care unit (ICU), early aggressive fluid replacement is the cornerstone of resuscitation. Traditionally employed static measures of fluid responsiveness have a poor predictive value. It is therefore imperative to employ dynamic measures of fluid responsiveness that take into account the heart lung interactions in the mechanically ventilated patients. The main objective of this study was to evaluate the reliability of one such non-invasive dynamic index: Plethysmographic variability index (PVI) compared to the widely employed Inferior vena cava distensibility index (dIVC).Methods: Seventy-six adult patients admitted at a tertiary care mixed ICU, who developed hypotension (MAP<65mmHg), were included in the study. PVI was recorded using the MASIMO-7 monitor and dIVC measurements done using Terason ultrasound. Based on the dIVC measurement threshold of 18%, the patients were classified into volume responders and non-responders. The hemodynamic, PVI and dIVC measurements were recorded at pre specified time points following a fluid challenge of 20 ml/kg crystalloid infusion.Results: Baseline PVI values were significantly higher in the responders (22.3±8.2) compared to non-responders (10.1±2.9) (p<0.001) and showed a declining trend at all time points in the responders. Similar declining trend was observed in the dIVC measurements. Overall, the Pearson correlation graph showed strong correlation between dIVC and PVI values at all time points (r=0.678, p=0.001). The ROC curve between the dIVC and PVI values revealed that Baseline PVI (Pre PVI) >15.5% discriminated between responders and non-responders with a 90.2% sensitivity and 75% specificity with an AUC of 0.84 (0.72-0.96) (p<0.001).Conclusions: There is good correlation between PVI values and measured dIVC values at baseline and following a fluid challenge. Thus, PVI may be an acceptable, real time, continuous, surrogate measure of fluid responsiveness in critically ill patients.

Publisher

Medip Academy

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3