Affiliation:
1. Departments of *Vascular Surgery and †Interventional Radiology, Mayo Clinic, Jacksonville, FL
Abstract
The purpose of this study was to review the outcome of endovascular abdominal aortic aneurysm repair (EVAR) using custom-made aortouni-iliac (AUI) devices with femorofemoral bypass. Between June 1999 and March 2001, 23 consecutive patients (1 female, 22 male) at high risk of open aortic aneurysm repair underwent EVAR with custom devices in an AUI configuration. The mean follow-up was 37 months (range 2–72 months), and the mean age was 76.8 years (range 67.5–88.7 years). Increased surgical risk was evidenced by 92% and 69% of patients with significant pulmonary or cardiac disease, respectively. The preoperative mean aneurysm diameter ( n = 23) 62 ± 8.2 mm was significantly greater than the postoperative diameter, ( n = 23) 54 ± 16.4 mm. Ten endoleaks occurred. Migration of the stent graft occurred in 9% ( n = 2). Secondary interventions were necessary in 23%, whereas tertiary interventions were required in 9%. Patients at high risk of open aneurysm repair received sufficient protection from aneurysm rupture with custom-made AUI devices.
Subject
Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine,Surgery
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献