ISOLATION OF F-WAVE FROM ELECTROCARDIOGRAM USING NEW LMS ALGORITHM

Author:

Ciaccio Edward J.1,Biviano Angelo B.1,Garan Hasan1

Affiliation:

1. Department of Medicine, Division of Cardiology, Columbia University Medical Center, New York, USA

Abstract

The electrocardiogram F-wave arising from atrial electrical activity is an important global measure for assessment of atrial fibrillation (AF). However, successful F-wave extraction from the ventricular waveform can be problematic. Herein, a new F-wave isolation technique is introduced. For analysis, electrocardiogram lead I (termed unfiltered or UNF-signals) was retrospectively analyzed (39 AF patients, 8.4-s recordings, 8192 sample points, 96 recordings in total). To measure the efficacy of isolation techniques, a synthetic F-wave (7.29 Hz) and an interference were added to each electrocardiogram signal. In the resulting composite signals, the average electrocardiogram QRST complex template was subtracted from each actual QRST (AVG-isolation). The QRST template was also adjusted using a new adaptive least mean-squares (LMS) algorithm, and subtracted from each actual QRST (termed LMS-isolation). Four spectral parameters were measured to assess isolated F-wave quality: the dominant amplitude (DA), dominant frequency (DF) and mean/standard deviation in spectral profile (MP/SP). Significant parameter differences between UNF/LMS and between AVG/LMS were determined. The electrocardiogram F-wave spectral parameters were significantly improved by incorporating LMS-isolation as compared to no isolation (p < 0.001). The F-wave spectral parameters were also significantly improved using LMS-isolation as compared with AVG-isolation (DA/MP/SP: p < 0.001; DF: p < 0.05). The DF was correctly identified as 7.29 ± 0.10 Hz using ensemble spectral analysis with the following percentages (UNF: 24.0%, AVG: 69.8%, LMS: 80.2%), and Fourier spectral analysis with the following percentages (UNF: 15.6%, AVG: 60.4%, LMS: 75.0%). The LMS algorithm is helpful to isolate the electrocardiogram F-wave from the ventricular component as measured by spectral analysis, when compared to the use of an average QRST subtraction template.

Publisher

National Taiwan University

Subject

Biomedical Engineering,Bioengineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3