STERILIZATION PERFORMANCE OF AUTOCLAVE UNITS ON CANNULAR MATERIALS

Author:

Sezdi Mana1,Yoleri Gamze2

Affiliation:

1. Department of Biomedical Device Technology, Istanbul University, 34320 Istanbul, Turkey

2. Department of Electrical and Electronics Engineering, Istanbul University, 34320 Istanbul, Turkey

Abstract

Autoclaves are devices that are used for sterilization of medical devices under high pressure and temperatures. As with all medical devices, the correct operation of autoclave units is vital for their performance and for successful sterilization. Thus, they should be tested to investigate their technical performance and biological effects within the studies of hospital quality control. Starting from setting the temperature and the pressure parameters up to taking out the materials from the autoclave after sterilization, all steps of the process need to be revised at these control stages. In this study, biological effects of sterilization were tested on microorganisms placed in cannular materials by using different temperatures and sterilization durations. As for the sterilization unit, a vertical type autoclave was used. The technical parameters of the autoclave during the sterilization process were measured by using a temperature–pressure data logger device. Bacillus subtilis var. niger strain was used to examine the biological performance of the sterilization unit. We performed different experiments by changing the temperature and the duration of the sterilization, and using several sizes of cannular materials. Experiments were made at 100°C, 95°C, 90°C, 85°C, 80°C, 75°C, 70°C and for 1 and 5 min. Additionally, two different cannula type sterile glass pipettes (1 and 10 ml) were used in experiments to compare the status of sterilization for different volumetric materials. Biological and technical results obtained for both test and control parameters were compared. The percent of bacteria reduction (Bacteria reduction% = (Test Number/Control Number) × 100) was calculated for biological tests. Technical tests resulted that the autoclave was not able to provide a stable output for temperatures from 70°C to 100°C, and for durations of 1 and 5 min. However, biological tests showed that the sterilization was achieved for the strain at all test conditions. It was observed that the autoclave provided technical requirements for sterilization even for short sterilization durations and low temperature, as such no microbial growth was observed. In short, the bacteria reduction percent was 100%. It was explained that the reason for biological sterilization at these low parameters is because the autoclave generated higher pressure and higher temperature than the set pressure and temperature values. Consequently, the results of the biological tests were supported by measuring the technical parameters of the autoclave.

Publisher

National Taiwan University

Subject

Biomedical Engineering,Bioengineering,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Production of kombucha from Kyllinga monocepala and its antibacterial activity;2ND INTERNATIONAL CONFERENCES ON SCIENCES AND MATHEMATICS (2ND ICSM);2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3