BIOCOMPATIBILITY EVALUATION OF DRUG RELEASING ABSORBABLE VASCULAR STENTS

Author:

Liu Si W.1ORCID,Weng Ching S.1,Wang Wei J.12,Liu Yuan H.3,Wu Vin C.4,Wang Ming C.1

Affiliation:

1. Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan, Taiwan, R. O. C.

2. Division of Nephrology, Department of Internal Medicine, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan, Taiwan, R. O. C.

3. Section of Cardiology, Cardiovascular Center Far Eastern Memorial Hospital, 21, Sec. 2, Nan-Ya South Road, Pan Chiao, New Taipei City, Taiwan, R. O. C.

4. Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan, R. O. C.

Abstract

This study examined the biocompatibility of blood vessels and a biodegradable drug-loaded vascular stent. The Traditional Chinese Medicine System Laboratory of Chung Yuan Christian University prepared the vascular stent, and our study verified the sustained release of drugs from the stent when it was within blood vessels. A platelet adhesion experiment revealed that stents with less surface roughness resulted in a reduction in the number of adhered platelets and decreased fibrinogen accumulation. The results of a hemolysis experiment verified that the hemolysis index was between 1% and 1.4%, within the range of no hemolysis and would not cause hypoxia. Subsequently, a drug release rate experiment indicated that the amount of released everolimus increased with time. The greatest amount of drug that was released occurred at 8[Formula: see text]h, with a release rate of 36.95%. A swelling rate experiment revealed that the degree of swelling of the hyaluronic acid (HA) that contained everolimus was 10 times less than that of the original HA; therefore, the use of a material with a low swelling rate in vascular stents did not immediately cause an obstruction in blood vessels. A lactate dehydrogenase (LDH) toxicity experiment revealed that the percentage of LDH released was 13–18%. This indicated that the cell viability was not affected and that there was no cytotoxicity; thus, the stent was suitable for use in blood vessels. This study proved that the prepared biodegradable drug-loaded vascular stent had favorable blood compatibility, no cytotoxicity, and a suitable drug release rate. Moreover, the drug release material was made from a material with a low degree of swelling. As a result of our findings, this new type of stent is suitable for application in blood vessels.

Funder

Ministry of Science and Technology, Taiwan

Publisher

National Taiwan University

Subject

Biomedical Engineering,Bioengineering,Biophysics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370